Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEvaluation of VOC measurments in the EXPOLIS study. Air Pollution Exposure Distributions within Adult Urban Urban Populations in Europe    Next AbstractDynamic properties of antennal responses to pheromone in two moth species »

Build Environ


Title:Assessing the indoor air quality and their predictor variable in 21 home offices during the Covid-19 pandemic in Norway
Author(s):Justo Alonso M; Moazami TN; Liu P; Jorgensen RB; Mathisen HM;
Address:"Department of Energy and Process Engineering, NTNU, Kolbjorn Hejes v 1B, Trondheim, Norway. Department of Industrial Economics and Technology Management, NTNU, Sem Saelands vei 5, Trondheim, Norway. Department: Architecture, Materials and Structures SINTEF Community, Hogskoleringen 13, Trondheim, Norway"
Journal Title:Build Environ
Year:2022
Volume:20220908
Issue:
Page Number:109580 -
DOI: 10.1016/j.buildenv.2022.109580
ISSN/ISBN:0360-1323 (Print) 1873-684X (Electronic) 0360-1323 (Linking)
Abstract:"In this study, concentrations of pollutants: formaldehyde, carbon dioxide (CO(2)), and total volatile organic compounds (TVOC) and parameters: indoor room temperature and relative humidity (RH) were measured in 21 home offices for at least one week in winter in Trondheim, Norway. Eleven of these were measured again for the same duration in summer. Potentially explanatory variables of these parameters were collected, including building and renovation year, house type, building location, trickle vent status, occupancy, wood stove, floor material, pets, RH, and air temperature. The association between indoor air pollutants and their potential predictor variables was analyzed using generalized estimation equations to determine the significant parameters to control pollutants. Significantly seasonal differences in concentrations were observed for CO(2) and formaldehyde, while no significant seasonal difference was observed for TVOC. For TVOC and formaldehyde, trickle vent, RH, and air temperature were among the most important predictor variables. Although higher concentrations of CO(2) were measured in cases where the trickle vent was closed, the most important predictor variables for CO(2) were season, RH, and indoor air temperature. The formaldehyde concentrations were higher outside working hours but mostly below health thresholds recommendations; for CO(2), 11 of the measured cases had indoor concentrations exceeding 1000 ppm in 10% of the measured time. For TVOC, the concentrations were above the recommended values by WHO in 73% of the cases. RH was generally low in winter. The temperature was generally kept over the recommended level of 22-24 degrees C during working hours"
Keywords:Co2 Formaldehyde General estimation equation Low-cost sensor Rh Room temperature Tvoc;
Notes:"PubMed-not-MEDLINEJusto Alonso, M Moazami, T N Liu, P Jorgensen, R B Mathisen, H M eng England 2022/09/14 Build Environ. 2022 Nov; 225:109580. doi: 10.1016/j.buildenv.2022.109580. Epub 2022 Sep 8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024