J Occup Environ Hyg


Title:Developing a new simplified method to determine diffusive uptake rates of volatile organic compounds in workplaces based on a fractional factorial designs approach
Author(s):Esteve W; Lhuillier F; Ravera C; Grzebyck M; Langlois E;
Address:"Laboratoire de Chimie Analytique Organique, Departement Metrologie des Polluants, Institut National de Recherche et de Securite (INRS), Vandoeuvre, France. williams.esteve@inrs.fr"
Journal Title:J Occup Environ Hyg
Year:2013
Volume:10
Issue:9
Page Number:505 - 518
DOI: 10.1080/15459624.2013.818232
ISSN/ISBN:1545-9632 (Electronic) 1545-9624 (Linking)
Abstract:"Exposure to organic vapors in the workplace is a source of occupational risk. Admissible exposure levels are tightly regulated and must be closely monitored. However, the complexity and slowness of the existing complete protocols to determine diffusive uptake rates through passive sampling have limited the use of this tool despite obvious advantages. In this study, we experimentally validate two simplified protocols to determine diffusive uptake rates with passive sampling. The proposed 2(6-3) and 2(6-2) fractional factorial designs were validated for toluene sampling using a (Gas Adsorbent Badge for Individual Exposure) GABIE-activated charcoal sampler in a controlled atmosphere. The uptake rate for this sampler had been determined previously using a full protocol. The uptake rates for all three protocols were similar, indicating that the proposed new designs can be substituted for classical full protocols. After validation of our protocols, uptake rates for new substances used as fuel additives (methyl and ethyl tert-butyl ethers, MTBE and ETBE) were determined on the same sampler using the 2(6-2) design. In these experiments, temperature appears to have a non-negligible influence on the uptake rates measured for these compounds. With some precautions of usage (ambient temperature below a determined limit temperature or at least exposure time >/=4 h) and storage (storage temperature = 4 degrees C) of the sampler, the experimental diffusive uptake rates determined by this method can be used with good confidence. Field experiments confirmed the experimental results, showing good agreement between active and passive sampling using the experimentally determined uptake rates"
Keywords:Air Pollutants/*analysis/chemistry Diffusion Environmental Monitoring/*methods Occupational Exposure/*analysis/prevention & control Toluene/*analysis/chemistry Volatile Organic Compounds/*analysis/chemistry Workplace;
Notes:"MedlineEsteve, Williams Lhuillier, Francine Ravera, Christel Grzebyck, Michel Langlois, Eddy eng Validation Study England 2013/08/10 J Occup Environ Hyg. 2013; 10(9):505-18. doi: 10.1080/15459624.2013.818232"

 