« Previous AbstractFrom the First to Third Generation of Neonicotinoids: Implication for Saving the Loss of Fruit Quality and Flavor by Pesticide Applications    Next AbstractEnhanced removal of mixed VOCs with different hydrophobicities by Tween 20 in a biotrickling filter: Kinetic analysis and biofilm characteristics »

Water Res


Title:Multi-omic studies on the toxicity variations in effluents from different units of reclaimed water treatment
Author(s):Deng Y; Zhang Y; Ren H;
Address:"State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, China. State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, China. Electronic address: yanzhang@nju.edu.cn"
Journal Title:Water Res
Year:2022
Volume:20211117
Issue:
Page Number:117874 -
DOI: 10.1016/j.watres.2021.117874
ISSN/ISBN:1879-2448 (Electronic) 0043-1354 (Linking)
Abstract:"The conventional reclaimed water technologies could not effectively remove the micropollutants. Although the health risks of these residual micropollutants have been evaluated by model calculation, few animal-based studies have been performed, which is essential for risk verification. Here, we used transcriptomic, metabolomic, and other biochemical techniques to reveal the toxicity variations of effluents from oxidation ditch (OD), coagulation tank (CT), biological aerated filter (BAF), and ultraviolet disinfection pool (UV) in a reclaimed water plant located in Nanjing, China. No evident toxicity reduction trend was observed along the treatment units. Compared with control and other three treatment unit effluents, long-term exposure to reclaimed water (UV effluent) aggravated oxidative stress in mice and induced abnormal lipid metabolism and immune response. Moreover, striking correlations were identified between multi-omic biomarkers (4 differentially expressed genes and 8 significant changes metabolites) and residual micropollutants (40 semi-volatile organic compounds and 6N-nitrosamines). Our results strongly highlight that the health risks of reclaimed water are mainly induced by the residual micropollutants, and more advanced treatments and stringent discharge standards are needed to ensure the safety of reclaimed water"
Keywords:"Animals China Disinfection Mice Wastewater *Water Pollutants, Chemical/analysis/toxicity *Water Purification Multi-omic Oxidative stress Reclaimed water Residual micropollutants Toxicity variations;"
Notes:"MedlineDeng, Yongfeng Zhang, Yan Ren, Hongqiang eng England 2021/11/24 Water Res. 2022 Jan 1; 208:117874. doi: 10.1016/j.watres.2021.117874. Epub 2021 Nov 17"

 