Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractTransition-metal-catalyzed carbonylation reactions of olefins and alkynes: a personal account    Next AbstractPersistence of fermentative process to phenolic toxicity in groundwater »

Environ Sci Technol


Title:Volatile organic compounds in small- and medium-sized commercial buildings in California
Author(s):Wu XM; Apte MG; Maddalena R; Bennett DH;
Address:"Department of Public Health Sciences, University of California, Davis, California, USA"
Journal Title:Environ Sci Technol
Year:2011
Volume:20110927
Issue:20
Page Number:9075 - 9083
DOI: 10.1021/es202132u
ISSN/ISBN:1520-5851 (Electronic) 0013-936X (Linking)
Abstract:"While small- and medium-sized commercial buildings (SMCBs) make up 96% of the commercial buildings in the U.S., serving a large variety of uses, little information is available on indoor air quality (IAQ) in SMCBs. This study investigated 37 SMCBs distributed across different sizes, ages, uses, and regions of California. We report indoor concentrations and whole building emission rates of a suite of 30 VOCs and aldehydes in these buildings. There was a considerable range in the concentrations for each of the contaminants, especially for formaldehyde, acetaldehyde, decamethylcyclopentasiloxane, d-limonene, 2-butoxyethanol, toluene, 2,2,4-trimethylpentanediol diisobutyrate, and diethylphthalate. The cause of higher concentrations in some building categories generally corresponded to expected sources, for example, chloroform was higher in restaurants and grocery stores, and formaldehyde was higher in retail stores and offices. Factor analysis suggests sources in SMCBs include automobile/traffic, cleaning products, occupant sources, wood products/coating, and plasticizers. The comparison to health guidelines showed that formaldehyde concentrations were above the chronic RELs required by the OEHHA (9 mug/m(3)) in 86% of the buildings. Data collected in this study begins to fill the knowledge gap for IAQ in SMCBs and helps us understand the indoor sources of VOCs to further improve indoor air quality in SMCBs"
Keywords:"Air Pollution, Indoor/*analysis Aldehydes Environmental Monitoring Volatile Organic Compounds/*analysis;"
Notes:"MedlineWu, Xiangmei May Apte, Michael G Maddalena, Randy Bennett, Deborah H eng Research Support, U.S. Gov't, Non-P.H.S. 2011/09/06 Environ Sci Technol. 2011 Oct 15; 45(20):9075-83. doi: 10.1021/es202132u. Epub 2011 Sep 27"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024