Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractValidation of atmospheric VOC measurements by proton-transfer-reaction mass spectrometry using a gas-chromatographic preseparation method    Next AbstractSla1p couples the yeast endocytic machinery to proteins regulating actin dynamics »

Environ Sci Technol


Title:"Online volatile organic compound measurements using a newly developed proton-transfer ion-trap mass spectrometry instrument during New England Air Quality Study--Intercontinental Transport and Chemical Transformation 2004: performance, intercomparison, and compound identification"
Author(s):Warneke C; Kato S; de Gouw JA; Goldan PD; Kuster WC; Shao M; Lovejoy ER; Fall R; Fehsenfeld FC;
Address:"National Oceanic and Atmospheric Administration, Aeronomy Laboratory, 325 Broadway, Boulder, Colorado 80305, USA. Carsten.Warneke@noaa.gov"
Journal Title:Environ Sci Technol
Year:2005
Volume:39
Issue:14
Page Number:5390 - 5397
DOI: 10.1021/es050602o
ISSN/ISBN:0013-936X (Print) 0013-936X (Linking)
Abstract:"We have used a newly developed proton-transfer ion-trap mass spectrometry (PIT-MS) instrument for online trace gas analysis of volatile organic compounds (VOCs) during the 2004 New England Air Quality Study-Intercontinental Transport and Chemical Transformation study. The PIT-MS instrument uses proton-transfer reactions with H3O+ ions to ionize VOCs, similarto a PTR-MS (proton-transfer reaction mass spectrometry) instrument but uses an ion trap mass spectrometer to analyze the product ions. The advantages of an ion trap are the improved identification of VOCs and a near 100% duty cycle. During the experiment, the PIT-MS instrument had a detection limit between 0.05 and 0.3 pbbv (S/N = 3 (signal-to-noise ratio)) for 2-min integration time for most tested VOCs. PIT-MS was used for ambient air measurements onboard a research ship and agreed well with a gas chromatography mass spectrometer). The comparison included oxygenated VOCs, aromatic compounds, and others such as isoprene, monoterpenes, acetonitrile, and dimethyl sulfide. Automated collision-induced dissociation measurements were used to determine the contributions of acetone and propanal to the measured signal at 59 amu; both species are detected at this mass and are thus indistinguishable in conventional PTR-MS"
Keywords:Air Movements Air Pollutants/*analysis Automation Environmental Monitoring/*methods *Internet Mass Spectrometry/*methods New England Organic Chemicals/analysis Volatilization;
Notes:"MedlineWarneke, Carsten Kato, Shuji De Gouw, Joost A Goldan, Paul D Kuster, William C Shao, Min Lovejoy, Edward R Fall, Ray Fehsenfeld, Fred C eng Comparative Study Evaluation Study Research Support, U.S. Gov't, Non-P.H.S. 2005/08/09 Environ Sci Technol. 2005 Jul 15; 39(14):5390-7. doi: 10.1021/es050602o"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024