Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Responses to chemical, physical and biological stresses: involvement of extracellular alarmones, pheromones and varisensors"    Next AbstractPrediction of gas collection efficiency and particle collection artifact for atmospheric semivolatile organic compounds in multicapillary denuders »

Environ Sci Technol


Title:"Performance of a high flow rate, thermally extractable multicapillary denuder for atmospheric semivolatile organic compound concentration measurement"
Author(s):Rowe MD; Perlinger JA;
Address:"Department of Civil and Environmental Engineering, Michigan Technological University, 1400 Townsend Dr., Houghton, Michigan 49931, USA"
Journal Title:Environ Sci Technol
Year:2010
Volume:44
Issue:6
Page Number:2098 - 2104
DOI: 10.1021/es903002k
ISSN/ISBN:0013-936X (Print) 0013-936X (Linking)
Abstract:"A high flow rate (300 L min(-1)) multicapillary denuder was designed to collect trace atmospheric semivolatile organic compounds (SOCs). The denuder is coated with a reusable, polydimethylsiloxane stationary phase as a nonselective absorbent for SOCs. A solvent-free thermal desorption method was developed, including sample cleanup, that is selective for nonpolar SOCs, and has low consumables cost per sample. The entire sample is transferred into the gas chromatograph to minimize the sampling time required to collect detectable analyte mass. Trace concentrations (0.1-100 pg m(-3)) of polychlorinated biphenyls and hexachlorobenzene were measured in the atmosphere near Lake Superior in sample times of 3.2-6.2 h. Overall method precision was determined using field duplicates and compared to the conventional high-volume sampler method. Method precision (coefficient of variation) of 16% was found for the high-flow denuder compared to 21% for the high-volume method. The relative difference between the two methods was 25%, with the high-flow denuder method giving generally lower concentrations. The high-flow denuder is an alternative to high-volume or passive samplers when it is desirable to separate gaseous from particle-associated SOCs upstream of a filter. The method is advantageous for studies that require high temporal resolution"
Keywords:Air Pollutants/*analysis/chemistry Atmosphere/chemistry Environmental Monitoring/instrumentation/*methods Hexachlorobenzene/analysis/chemistry Polychlorinated Biphenyls/analysis/chemistry Volatile Organic Compounds/*analysis/chemistry;
Notes:"MedlineRowe, Mark D Perlinger, Judith A eng Evaluation Study Research Support, Non-U.S. Gov't 2010/02/13 Environ Sci Technol. 2010 Mar 15; 44(6):2098-104. doi: 10.1021/es903002k"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024