Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"The stress effect of atrazine on the inducible defense traits of Daphnia pulex in response to fish predation risk: Evidences from morphology, life history traits, and expression of the defense-related genes"    Next AbstractThe screening of volatile markers for hepatocellular carcinoma »

Talanta


Title:"A simple method for the trace determination of methanol, ethanol, acetone and pentane in human breath and in the ambient air by preconcentration on solid sorbents followed by gas chromatography"
Author(s):Qin T; Xu X; Polak T; Pacakova V; Stulik K; Jech L;
Address:"The Research Centre for Eco-environmental Chemistry, Academia Sinica, Beijing 100 085, People's Republic of China"
Journal Title:Talanta
Year:1997
Volume:44
Issue:9
Page Number:1683 - 1690
DOI: 10.1016/s0039-9140(97)00073-8
ISSN/ISBN:0039-9140 (Print) 0039-9140 (Linking)
Abstract:"A simple technique has been developed for preconcentration of gaseous trace organic compounds on solid sorbents, followed by gas chromatography. The sorbent is packed in a cartridge from a syringe needle placed in the gas chromatographic injector and the analytes previously adsorbed are thermally desorbed at the injector temperature and then directly swept by the carrier gas into the column. The system has been tested for a charcoal-based adsorbent and silica gel, with pentane, methanol, ethanol and acetone as the model analytes. The procedure is rapid, the detection limits vary from a few nmol l(-1) to values below 0.1 nmol l(-1) (i.e., a few ppb), the linear dynamic range amounts to at least five concentration decades and a typical relative standard deviation is 10% at the nmol l(-1) concentrations. It has been shown that the method is readily applicable to determination of instantaneous concentrations of the analytes in natural and industrial atmosphere and to their monitoring in human breath which is important for medical and hygienic practice. In general, the procedure is applicable to low-molecular volatile organic compounds"
Keywords:
Notes:"PubMed-not-MEDLINEQin, T Xu, X Polak, T Pacakova, V Stulik, K Jech, L eng Netherlands 2008/10/31 Talanta. 1997 Sep; 44(9):1683-90. doi: 10.1016/s0039-9140(97)00073-8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024