Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Phenological Features of the Spongy Moth, Lymantria dispar (L.) (Lepidoptera: Erebidae), in the Northernmost Portions of Its Eurasian Range"    Next Abstract"Physicochemical Attributes, Aroma Profile, and Sensory Quality of Organic Crimson Crisp Apples after Storage" »

Water Res


Title:Optimization of the hydrolytic-acidogenic anaerobic digestion stage (55 degrees C) of sewage sludge: influence of pH and solid content
Author(s):Ponsa S; Ferrer I; Vazquez F; Font X;
Address:"Department of Chemical Engineering, Escola Tecnica Superior d'Enginyeria, Universitat Autonoma de Barcelona, Bellaterra, Cerdanyola del Valles, 08193 Barcelona, Spain"
Journal Title:Water Res
Year:2008
Volume:20080710
Issue:14
Page Number:3972 - 3980
DOI: 10.1016/j.watres.2008.07.002
ISSN/ISBN:0043-1354 (Print) 0043-1354 (Linking)
Abstract:"In conventional single-stage anaerobic digestion processes, hydrolysis is regarded as the rate-limiting step in the degradation of complex organic compounds, such as sewage sludge. Two-stage systems have been proposed to enhance this process. However, so far it is not clear which are the best conditions for a two-stage anaerobic digestion process of sewage sludge, in terms of temperature and hydraulic retention time of each stage. The aim of this work was to determine the optimal conditions for the hydrolytic-acidogenic stage treating real sludge with a high concentration of total solids (40-50gL(-1)) and volatile solids (25-30gL(-1)), named high concentration sludge. The variables considered for this first stage were: hydraulic retention time (1-4 days) and temperature (55 and 65 degrees C). Maximum volatile fatty acids generation was obtained at 4 days and 3 days hydraulic retention time for 55 degrees C and 65 degrees C, respectively. Consequently, 4 days hydraulic retention time and temperature of 55 degrees C were set as the working conditions for the hydrolytic-acidogenic stage treating high concentration sludge. The results obtained when operating with high concentration sludge were compared with a low concentration sludge consisting of 17-28gL(-1) total solids and 13-21gL(-1) volatile solids. The effect of decreasing the influent sludge pH, when working at the optimal conditions established, was also evaluated"
Keywords:"Anaerobiosis Hydrogen-Ion Concentration Hydrolysis Oxidation-Reduction Sewage/*chemistry Water Pollutants, Chemical Water Purification;"
Notes:"MedlinePonsa, Sergio Ferrer, Ivet Vazquez, Felicitas Font, Xavier eng Research Support, Non-U.S. Gov't England 2008/08/09 Water Res. 2008 Aug; 42(14):3972-80. doi: 10.1016/j.watres.2008.07.002. Epub 2008 Jul 10"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024