Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractUrinary volatile organic compound markers and colorectal anastomotic leakage    Next AbstractToxicity of organic extraction reagents to anaerobic bacteria »

Materials (Basel)


Title:Realization of Microfluidic Preconcentrator for N-Pentane Traces Impurities from the Gaseous Media
Author(s):Platonov V; Sharma P; Ledyaev M; Anikina MA; Djuzhev NA; Chinenkov MY; Tripathi N; Parveen S; Ahmad R; Pavelyev V; Melaibari AA;
Address:"Samara National Research University, 34, Moskovskoye Shosse, 443086 Samara, Russia. School of Electronics Engineering (SENSE), Vellore Institute of Technology (VIT), Vellore 632014, India. Scientific Research Institute of the Department of Gas Processing, Hydrogen and Special Technologies, Samara State Technical University, 443100 Samara, Russia. National Research University of Electronic Technology (MIET), 124498 Moscow, Russia. Central Instrumentation Facility, Jamia Millia Islamia, New Delhi 110025, India. Centre for Nanoscience and Nanotechnology, Jamia Millia Islamia, New Delhi 110025, India. Center of Nanotechnology, King Abdulaziz University, Jeddha 22254, Saudi Arabia"
Journal Title:Materials (Basel)
Year:2022
Volume:20221115
Issue:22
Page Number: -
DOI: 10.3390/ma15228090
ISSN/ISBN:1996-1944 (Print) 1996-1944 (Electronic) 1996-1944 (Linking)
Abstract:"In this paper, we present the work of designing and fabricating a new generation of microelectromechanical systems (MEMS) based microfluidic preconcentrators (MFP) for volatile organic compounds (VOCs) quantification. The main objective of this work is to quantify the n-pentane impurities using MFP for sample preparation. The MFP was analyzed using Hewlett-Packard 5890 gas chromatography, having a flame ionization detector under isothermal conditions. The proposed MFP system includes two-microfluidic preconcentrators for continuous action and a system of four 3/2 solenoid valves with a control unit. Microfluidic preconcentrators were placed on metal plates and have circular channels filled with Al2O3 (50 mum), n-octane ResSil-C (80/100 mesh) sorbents of one nature and are hyphenated with the Peltier elements to regulate the temperature of sorption and desorption. The n-pentane quantitative determination was carried out using a calibration plot of gas mixtures on a successive dilution with the nitrogen. This study shows that the microfluidic preconcentrator system with Al2O3 and n-Octane ResSil-C sorbent concentrates the n-pentane traces up to 41 to 47 times from the gas mixture with the standard deviation of
Keywords:Mems microfabricated systems microfluidic preconcentrators;
Notes:"PubMed-not-MEDLINEPlatonov, Vladimir Sharma, Prachi Ledyaev, Mikhail Anikina, Maria A Djuzhev, Nikolay Alekseevich Chinenkov, Maksim Yuryevich Tripathi, Nishant Parveen, Sania Ahmad, Rafiq Pavelyev, Vladimir Melaibari, Ammar A eng Switzerland 2022/11/27 Materials (Basel). 2022 Nov 15; 15(22):8090. doi: 10.3390/ma15228090"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-09-2024