Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Pulsed mass recruitment by a stingless bee, Trigona hyalinata"    Next AbstractSexual responses of male rats to odours from female rats in oestrus are not affected by female germ-free status »

J Chromatogr A


Title:Quantification of volatile sulfur compounds in complex gaseous matrices by solid-phase microextraction
Author(s):Nielsen AT; Jonsson S;
Address:"Department of Water and Environmental Studies, Linkoping University, Sweden. annni@tema.liu.se"
Journal Title:J Chromatogr A
Year:2002
Volume:963
Issue:1-Feb
Page Number:57 - 64
DOI: 10.1016/s0021-9673(02)00556-3
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"Procedures were assessed for quantifying nine volatile sulfur compounds found in complex gaseous samples collected at a biogas-production plant and a sewage treatment plant. The target compounds were extracted by solid-phase microextraction (using the 75-microm Carboxen-polydimethylsiloxane fiber coating) at 22 degrees C for 20 min, and analyzed by GC-MS. Detection limits ranged between 1 pptv (v/v) for carbon disulfide and 470 pptv (v/v) for hydrogen sulfide. High amounts of organic compounds were found during full-scan analysis of the samples and standard additions to individual sub-samples revealed that the analysis was subject to matrix effects. However, the functions obtained by standard additions were still linear and quantification was possible for all the compounds tested except hydrogen sulfide. No detectable losses were observed during storage in the sampling containers, made of Tedlar film, over a storage period of 20 h. However, water permeated through the walls and the relative humidity in the bag increased during storage until it reached the ambient level. Finally, it was shown that the drying agent, CaCl2, caused no detectable losses of any of the compounds"
Keywords:Gas Chromatography-Mass Spectrometry/methods Gases/*chemistry Sensitivity and Specificity Sulfur Compounds/*analysis Volatilization;
Notes:"MedlineNielsen, Annika T Jonsson, Susanne eng Research Support, Non-U.S. Gov't Netherlands 2002/08/22 J Chromatogr A. 2002 Jul 19; 963(1-2):57-64. doi: 10.1016/s0021-9673(02)00556-3"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024