Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractWine aroma response to different participation of selected Hanseniaspora uvarum in mixed fermentation with Saccharomyces cerevisiae    Next AbstractThe Rice Transcription Factor WRKY53 Suppresses Herbivore-Induced Defenses by Acting as a Negative Feedback Modulator of Mitogen-Activated Protein Kinase Activity »

Environ Sci Technol


Title:Physical modeling of air flow during air sparging remediation
Author(s):Hu L; Wu X; Liu Y; Meegoda JN; Gao S;
Address:"State Key Laboratory of Hydro-Science and Engineering, Department of Hydraulic Engineering, Tsinghua University, Beijing 100084, China. gehu@tsinghua.edu.cn"
Journal Title:Environ Sci Technol
Year:2010
Volume:44
Issue:10
Page Number:3883 - 3888
DOI: 10.1021/es903853v
ISSN/ISBN:0013-936X (Print) 0013-936X (Linking)
Abstract:"Air sparging (AS) is one of the most efficient techniques for remediating saturated soils and groundwater contaminated with volatile organic compounds. A series of physical modeling tests for different sizes of porous media under varied injection pressure were conducted to investigate the effect of particle size and air injection pressure on size and shape of the zone of influence (ZOI). The test results show that ZOI can be expressed by two components: the horizontal expansion due to pneumatic fracture or preferential intrusion around the injection point and the angle of ZOI which is the angle between the vertical line and the boundary of ZOI. There exists a limited angle of ZOI for each type of porous media. The measured minimum and maximum air injection pressures in 1g tests are compared with corresponding theoretical values, and it is found that the measured minimum injection pressure is slightly lower than the theoretical value, while the measured maximum injection pressure is much higher than the theoretical maximum injection pressure. Centrifugal test results confirmed nonapplicability of theoretical maximum injection pressure to air sparging design. All of the above provide valuable information for design and theoretical modeling of air sparging for groundwater remediation"
Keywords:"Air Pollutants/*isolation & purification Environmental Restoration and Remediation/*methods *Models, Theoretical;"
Notes:"MedlineHu, Liming Wu, Xiaofeng Liu, Yan Meegoda, Jay N Gao, Shengyan eng Research Support, Non-U.S. Gov't 2010/04/30 Environ Sci Technol. 2010 May 15; 44(10):3883-8. doi: 10.1021/es903853v"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024