Indoor Air


Title:Unexpected increase in indoor pollutants after the introduction of a smoke-free policy in a correctional center
Author(s):He C; Knibbs LD; Tran Q; Wang H; Laiman R; Wang B; Gu Y; Morawska L;
Address:"International Laboratory for Air Quality and Health, Institute of Health and Biomedical Innovation, Queensland University of Technology (QUT), Brisbane, Qld, Australia. School of Population Health, The University of Queensland, Herston, Qld, Australia. Faculty of Environmental Engineering, National University of Civil Engineering, Hanoi, Vietnam. Department of Applied Physics, University of Eastern Finland, Kuopio, Finland. Department of Environmental Engineering, Jinan University, Guangzhou, China"
Journal Title:Indoor Air
Year:2016
Volume:20150810
Issue:4
Page Number:623 - 633
DOI: 10.1111/ina.12238
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"Correctional centers (prisons) are one of the few non-residential indoor environments where smoking is still permitted. However, few studies have investigated indoor air quality (IAQ) in these locations. We quantified the level of inmate and staff exposure to secondhand smoke, including particle number (PN) count, and we assessed the impact of the smoking ban on IAQ. We performed measurements of indoor and outdoor PM2.5 and PN concentrations, personal PN exposure levels, volatile organic compounds (VOCs), and nicotine both before and after a complete indoor smoking ban in an Australian maximum security prison. Results show that the indoor 24-h average PM2.5 concentrations ranged from 6 (+/-1) mug/m(3) to 17 (+/-3) mug/m(3) pre-ban. The post-ban levels ranged from 7 (+/-2) mug/m(3) to 71 (+/-43) mug/m(3) . While PM2.5 concentrations decreased in one unit post-ban, they increased in the other two units. Similar post-ban increases were also observed in levels of PN and VOCs. We describe an unexpected increase of indoor pollutants following a total indoor smoking ban in a prison that was reflected across multiple pollutants that are markers of smoking. We hypothesise that clandestine post-ban smoking among inmates may have been the predominant cause"
Keywords:"Air Pollution, Indoor/*analysis Australia Environmental Monitoring/*statistics & numerical data Humans Nicotine/analysis Particulate Matter/analysis Prisons/*legislation & jurisprudence *Smoke-Free Policy Tobacco Smoke Pollution/*analysis Volatile Organic;"
Notes:"MedlineHe, C Knibbs, L D Tran, Q Wang, H Laiman, R Wang, B Gu, Y Morawska, L eng Research Support, Non-U.S. Gov't England 2015/07/18 Indoor Air. 2016 Aug; 26(4):623-33. doi: 10.1111/ina.12238. Epub 2015 Aug 10"

 