Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSpruce Budworm (Lepidoptera: Tortricidae) Oral Secretions I: Biology and Function    Next Abstract"Selection of gas standards, gas chromatography column and adsorbents for the measurement of very volatile organic compounds (C(1)-C(6)) in indoor air" »

Anal Methods


Title:On the use of Carbograph 5TD as an adsorbent for sampling VVOCs: validation of an analytical method
Author(s):Even M; Juritsch E; Richter M;
Address:"Bundesanstalt fur Materialforschung und -prufung (BAM), Unter den Eichen 87, 12205 Berlin, Germany. matthias.richter@bam.de"
Journal Title:Anal Methods
Year:2023
Volume:20230810
Issue:31
Page Number:3810 - 3821
DOI: 10.1039/d3ay00677h
ISSN/ISBN:1759-9679 (Electronic) 1759-9660 (Linking)
Abstract:"A standardised method for the analysis of very volatile organic compounds (VVOCs) in indoor air is still missing. This study evaluates the use of Carbograph 5TD as an adsorbent for 60 compounds (47 VVOCs + 13 VOCs) by comparing their recoveries with different spiking modes. The influence of the spiking of the tubes in dry nitrogen, humidified air or along the whole flushing duration mimicking real sampling was investigated. 49 substances (36 VVOCs from C(1) to C(6)) had recoveries over 70% on the adsorbent in humidified air and were validated. The linearity of the calibration curves was verified for every spiking mode and the limits of detection (LOD) and quantification (LOQ) were determined. The LOQs were lower than the existing indoor air guideline values. The robustness of the method was considered by studying the influence of the sampling volume, the sampling flow rate, the humidity level and the storage of the tubes. In general, the most volatile or polar substances were the less robust ones. The combined measurement uncertainty was calculated and lies below 35% for a vast majority of the substances. An example of an emission chamber test using polyurethane foam is shown: Carbograph 5TD performs much better than Tenax(R) TA for VVOCs and emissions from n-butane were quantified with combined measurement uncertainty"
Keywords:
Notes:"PubMed-not-MEDLINEEven, Morgane Juritsch, Elevtheria Richter, Matthias eng England 2023/07/31 Anal Methods. 2023 Aug 10; 15(31):3810-3821. doi: 10.1039/d3ay00677h"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 03-07-2024