Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPrenatal exposure to a low dose of BPS causes sex-dependent alterations to vascular endothelial function in adult offspring    Next Abstract"Prosystemin from potato, black nightshade, and bell pepper: primary structure and biological activity of predicted systemin polypeptides" »

Chemosphere


Title:Solid-phase microextraction (SPME) for determination of geosmin and 2-methylisoborneol in volatile emissions from soil disturbance
Author(s):Conrady MW; Bauer M; Jo KD; Cropek DM; Busby RR;
Address:"U.S. Army Construction Engineering Research Laboratory, Champaign, IL, USA. Education Center of the German Armed Forces, Mannheim, DE, USA. U.S. Army Construction Engineering Research Laboratory, Champaign, IL, USA. Electronic address: ryan.r.busby@usace.army.mil"
Journal Title:Chemosphere
Year:2021
Volume:20210626
Issue:
Page Number:131333 -
DOI: 10.1016/j.chemosphere.2021.131333
ISSN/ISBN:1879-1298 (Electronic) 0045-6535 (Linking)
Abstract:"A method is described here for the concentration and determination of geosmin and 2-methylisoborneol (2-MIB) from the gaseous phase, with translation to field collection and quantification from soil disturbances in situ. The method is based on the use of solid-phase microextraction (SPME) fibers for adsorption of volatile chemicals from the vapor phase, followed by desorption into a gas chromatograph-mass spectrometer (GC-MS) for analysis. The use of a SPME fiber allows simple introduction to the GC-MS without further sample preparation. Several fiber sorbent types were studied and the 50/30 mum DVB/CAR/PDMS was the best performer to maximize the detected peak areas of both analytes combined. Factors such as extraction temperature and time along with desorption temperature and time were explored with respect to analyte recovery. An extraction temperature of 30 degrees C for 10 min, with a desorption temperature of 230 degrees C for 4 min was best for the simultaneous analysis of both geosmin and 2-MIB without complete loss of either one. The developed method was used successfully to measure geosmin and 2-MIB emission from just above disturbed and undisturbed soils, indicating that this method detects both compounds readily from atmospheric samples. Both geosmin and 2-MIB were present as background concentrations in the open air, while disturbed soils emitted much higher concentrations of both compounds. Surprisingly, 2-MIB was always detected at higher concentrations than geosmin, indicating that a focus on its detection may be more useful for soil emission monitoring and more sensitive to low levels of soil disturbance"
Keywords:Camphanes Gas Chromatography-Mass Spectrometry Naphthols *Soil *Solid Phase Microextraction 2-Methylisoborneol Geosmin Solid-phase microextraction Volatile organic compounds;
Notes:"MedlineConrady, Morgan W Bauer, Markus Jo, Kyoo D Cropek, Donald M Busby, Ryan R eng England 2021/07/06 Chemosphere. 2021 Dec; 284:131333. doi: 10.1016/j.chemosphere.2021.131333. Epub 2021 Jun 26"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024