Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"A new method for determining the initial mobile formaldehyde concentrations, partition coefficients, and diffusion coefficients of dry building materials"    Next AbstractCharacteristics of surface ozone at an urban site of Xi'an in Northwest China »

Talanta


Title:2D spatiotemporal visualization system of expired gaseous ethanol after oral administration for real-time illustrated analysis of alcohol metabolism
Author(s):Wang X; Ando E; Takahashi D; Arakawa T; Kudo H; Saito H; Mitsubayashi K;
Address:"Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunnkyo-ku, Tokyo 113-8510, Japan"
Journal Title:Talanta
Year:2010
Volume:20100429
Issue:3
Page Number:892 - 898
DOI: 10.1016/j.talanta.2010.04.048
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"A novel 2-dimensional spatiotemporal visualization system of expired gaseous ethanol after oral administration for real-time illustrated analysis of alcohol metabolism has been developed, which employed a low level light CCD camera to detect chemiluminescence (CL) generated by catalytic reactions of standard gaseous ethanol and expired gaseous ethanol after oral administration. First, the optimization of the substrates for visualization and the concentration of luminol solution for CL were investigated. The cotton mesh and 5.0 mmol L(-1) luminol solution were selected for further investigations and this system is useful for 0.1-20.0 mmol L(-1) of H(2)O(2) solution. Then, the effect of pH condition of Tris-HCl buffer solution was also evaluated with CL intensity and under the Tris-HCl buffer solution pH 10.1, a wide calibration range of standard gaseous ethanol (30-400 ppm) was obtained. Finally, expired air of 5 healthy volunteers after oral administration was measured at 15, 30, 45, 60, 75, 90, 105 and 120 min after oral administration, and this system showed a good sensitivity on expired gaseous ethanol for alcohol metabolism. The peaks of expired gaseous ethanol concentration appeared within 30 min after oral administration. During the 30 min after oral administration, the time variation profile based on mean values showed the absorption and distribution function, and the values onward showed the elimination function. The absorption and distribution of expired gaseous ethanol in 5 healthy volunteers following first-order absorption process were faster than the elimination process, which proves efficacious of this system for described alcohol metabolism in healthy volunteers. This system is expected to be used as a non-invasive method to detect VOCs as well as several other drugs in expired air for clinical purpose"
Keywords:Alcohols/metabolism Ethanol/administration & dosage/*analysis/pharmacokinetics *Exhalation Gases Humans Luminescent Measurements/methods Luminol Volatile Organic Compounds/analysis;
Notes:"MedlineWang, Xin Ando, Eri Takahashi, Daishi Arakawa, Takahiro Kudo, Hiroyuki Saito, Hirokazu Mitsubayashi, Kohji eng Research Support, Non-U.S. Gov't Netherlands 2010/08/04 Talanta. 2010 Aug 15; 82(3):892-8. doi: 10.1016/j.talanta.2010.04.048. Epub 2010 Apr 29"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024