Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Divergence of species-specific protein sex pheromone blends in two related, nonhybridizing newts (Salamandridae)"    Next AbstractContinuous real time breath gas monitoring in the clinical environment by proton-transfer-reaction-time-of-flight-mass spectrometry »

J Chromatogr A


Title:Needle trap micro-extraction for VOC analysis: effects of packing materials and desorption parameters
Author(s):Trefz P; Kischkel S; Hein D; James ES; Schubert JK; Miekisch W;
Address:"Department of Anaesthesia and Intensive Care, University of Rostock, Rostock, Germany"
Journal Title:J Chromatogr A
Year:2012
Volume:20111109
Issue:
Page Number:29 - 38
DOI: 10.1016/j.chroma.2011.10.077
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"Combining advantages of SPE and SPME needle trap devices (NTD) represent promising new tools for a robust and reproducible sample preparation. This study was intended to investigate the effect of different packing materials on efficacy and reproducibility of VOC analysis by means of needle trap micro extraction (NTME). NTDs with a side hole design and containing different combinations of PDMS, DVB and Carbopack X and Carboxen 1000 and NTDs containing a single layer organic polymer of methacrylic acid and ethylene glycol dimethacrylate were investigated with respect to reproducibility, LODs and LOQs, carry over and storage. NTDs were loaded with VOC standard gas mixtures containing saturated and unsaturated hydrocarbons, oxygenated and aromatic compounds. Volatile substances were thermally desorbed from the NTDs using fast expansive flow technique and separated, identified and quantified by means of GC-MS. Optimal desorption temperatures between 200 and 290 degrees C could be identified for the different types of NTDs with respect to desorption efficiency and variation. Carry over was below 6% for polymer packed needles and up to 67% in PDMS/Carboxen 1000 NTDs. Intra and inter needle variation was best for polymer NTDs and consistently below 9% for this type of NTD. LODs and LOQs were in the range of some ng/L. Sensitivity of the method could be improved by increasing sample volume. NTDs packed with a copolymer of methacrylic acid and ethylene glycol dimethacrylate were universally applicable for sample preparation in VOC analysis. If aromatic compounds were to be determined DVB/Carboxen 1000 and DVB/Carbopack X/Carboxen 1000 devices could be considered as an alternative. PDMS/Carbopack X/Carboxen 1000 NTDs may represent a good alternative for the analysis of hydrocarbons and aldehydes. NTME represents a powerful tool for different application areas, from environmental monitoring to breath analysis"
Keywords:Adsorption Chemical Fractionation/*instrumentation/*methods Dimethylpolysiloxanes Gas Chromatography-Mass Spectrometry Limit of Detection Methacrylates Needles Reproducibility of Results Temperature Vinyl Compounds Volatile Organic Compounds/analysis/*iso;
Notes:"MedlineTrefz, Phillip Kischkel, Sabine Hein, Dietmar James, Ellwood Sean Schubert, Jochen K Miekisch, Wolfram eng Netherlands 2011/12/06 J Chromatogr A. 2012 Jan 6; 1219:29-38. doi: 10.1016/j.chroma.2011.10.077. Epub 2011 Nov 9"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024