Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBiological monitoring and personal exposure to traffic-related air pollutants of elementary school-age children living in a metropolitan area    Next AbstractHematopoietic stem cell mobilization: updated conceptual renditions »

Environ Sci Technol


Title:Development of Solid Ceramic Dosimeters for the Time-Integrative Passive Sampling of Volatile Organic Compounds in Waters
Author(s):Bonifacio RG; Nam GU; Eom IY; Hong YS;
Address:"Department of Environmental Engineering, Daegu University , 201 Daegudae-ro, Jillyang-eup, Gyeongsan-si, Gyeongsangbuk-do, 38453 Republic of Korea. Department of Chemistry, Daegu Catholic University , 330 Geumrak-ri, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do, 38430 Republic of Korea"
Journal Title:Environ Sci Technol
Year:2017
Volume:20171010
Issue:21
Page Number:12557 - 12565
DOI: 10.1021/acs.est.7b03678
ISSN/ISBN:1520-5851 (Electronic) 0013-936X (Linking)
Abstract:"Time-integrative passive sampling of volatile organic compounds (VOCs) in water can now be accomplished using a solid ceramic dosimeter. A nonporous ceramic, which excludes the permeation of water, allowing only gas-phase diffusion of VOCs into the resin inside the dosimeter, effectively captured the VOCs. The mass accumulation of 11 VOCs linearly increased with time over a wide range of aqueous-phase concentrations (16.9 to 1100 mug L(-1)), and the linearity was dependent upon the Henry's constant (H). The average diffusivity of the VOCs in the solid ceramic was 1.46 x 10(-10) m(2) s(-1) at 25 degrees C, which was 4 orders of magnitude lower than that in air (8.09 x 10(-6) m(2) s(-1)). This value was 60% greater than that in the water-permeable porous ceramic (0.92 x 10(-10) m(2) s(-1)), suggesting that its mass accumulation could be more effective than that of porous ceramic dosimeters. The mass accumulation of the VOCs in the solid ceramic dosimeter increased in the presence of salt (>/=0.1 M) and with increasing temperature (4 to 40 degrees C) but varied only slightly with dissolved organic matter concentration. The solid ceramic dosimeter was suitable for the field testing and measurement of time-weighted average concentrations of VOC-contaminated waters"
Keywords:*Ceramics *Radiation Dosimeters Volatile Organic Compounds;
Notes:"MedlineBonifacio, Riza Gabriela Nam, Go-Un Eom, In-Yong Hong, Yong-Seok eng 2017/09/28 Environ Sci Technol. 2017 Nov 7; 51(21):12557-12565. doi: 10.1021/acs.est.7b03678. Epub 2017 Oct 10"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024