Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractGas chromatography coupled to tunable pulsed glow discharge time-of-flight mass spectrometry for environmental analysis    Next AbstractImproving pulsed radiofrequency glow discharge for time-of-flight mass spectrometry simultaneous elemental and molecular analysis »

Anal Bioanal Chem


Title:Elemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometry
Author(s):Sola-Vazquez A; Costa-Fernandez JM; Pereiro R; Sanz-Medel A;
Address:"Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Oviedo, Spain"
Journal Title:Anal Bioanal Chem
Year:2011
Volume:20110611
Issue:9
Page Number:2771 - 2777
DOI: 10.1007/s00216-011-5145-6
ISSN/ISBN:1618-2650 (Electronic) 1618-2642 (Linking)
Abstract:"A new prototype based on a microsecond pulsed glow discharge ion source coupled to a time-of-flight mass spectrometer was recently designed, constructed and analytically evaluated in our laboratory for simultaneous collection of elemental and molecular information, and as a gas-chromatographic detector of compounds of environmental concern. To investigate further the analytical capabilities of such a new setup, its capability for the determination of element ratios in volatile organic halogenated compounds has been explored. Moreover, compound-independent calibration has been carried out with the prototype as well. The results demonstrated that the intensity ratios (analyte to internal standard) were linear with the corresponding ratio of concentrations. Both for chlorine and bromine (measured in the prepeak) and for BrC (measured in the plateau) the slope was 1 and the intercept was 0. Moreover, detection limits were improved by more than 1 order of magnitude as compared with using external calibration. The applicability of the proposed approach has been demonstrated for the straightforward determination of chloroform in drinking and river waters"
Keywords:
Notes:"PubMed-not-MEDLINESola-Vazquez, Auristela Costa-Fernandez, Jose M Pereiro, Rosario Sanz-Medel, Alfredo eng Germany 2011/06/15 Anal Bioanal Chem. 2011 Nov; 401(9):2771-7. doi: 10.1007/s00216-011-5145-6. Epub 2011 Jun 11"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024