Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAerosols generated by hardcopy devices and other electrical appliances    Next AbstractHuman sensory response to acetone/air mixtures »

Chemosphere


Title:Impact of operating wood-burning fireplace ovens on indoor air quality
Author(s):Salthammer T; Schripp T; Wientzek S; Wensing M;
Address:"Fraunhofer WKI, Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54 E, 38108 Braunschweig, Germany. Electronic address: tunga.salthammer@wki.fraunhofer.de. Fraunhofer WKI, Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54 E, 38108 Braunschweig, Germany"
Journal Title:Chemosphere
Year:2014
Volume:20131222
Issue:
Page Number:205 - 211
DOI: 10.1016/j.chemosphere.2013.11.067
ISSN/ISBN:1879-1298 (Electronic) 0045-6535 (Linking)
Abstract:"The use of combustion heat sources like wood-burning fireplaces has regained popularity in the past years due to increasing energy costs. While the outdoor emissions from wood ovens are strictly regulated in Germany, the indoor release of combustion products is rarely considered. Seven wood burning fireplaces were tested in private homes between November 2012 and March 2013. The indoor air quality was monitored before, during and after operation. The following parameters were measured: ultra-fine particles (5.6-560 nm), fine particles (0.3-20 mum), PM2.5, NOx, CO, CO2, formaldehyde, acetaldehyde, volatile organic compounds (VOCs) and benzo[a]pyrene (BaP). Most ovens were significant sources of particulate matter. In some cases, an increase of benzene and BaP concentrations was observed in the indoor air. The results illustrate that wood-burning fireplaces are potential sources of indoor air contaminants, especially ultra-fine particles. Under the aspect of lowering indoor air exchange rates and increasing the use of fuels with a net zero-carbon footprint, indoor combustion sources are an important topic for the future. With regards to consumer safety, product development and inspection should consider indoor air quality in addition to the present fire protection requirements"
Keywords:"Air Pollution, Indoor/*analysis Cooking/*instrumentation Germany Particulate Matter Volatile Organic Compounds/*analysis *Wood Fireplace oven Gaseous emissions Guideline values Indoor air quality Particles Wood combustion;"
Notes:"MedlineSalthammer, Tunga Schripp, Tobias Wientzek, Sebastian Wensing, Michael eng Research Support, Non-U.S. Gov't England 2013/12/25 Chemosphere. 2014 May; 103:205-11. doi: 10.1016/j.chemosphere.2013.11.067. Epub 2013 Dec 22"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024