Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEnvironmental exposure to volatile organic compounds is associated with endothelial injury    Next Abstract"Effects of a small, volatile bacterial molecule on Pseudomonas aeruginosa bacteria using whole cell high-resolution magic angle spinning nuclear magnetic resonance spectroscopy and genomics" »

Sci Total Environ


Title:Air quality and well-being perception in subjects attending university libraries in Modena (Italy)
Author(s):Righi E; Aggazzotti G; Fantuzzi G; Ciccarese V; Predieri G;
Address:"Department of Hygiene, Microbiology and Biostatistics, University of Modena and Reggio Emilia, Italy. e.righi@unimo.it"
Journal Title:Sci Total Environ
Year:2002
Volume:286
Issue:1-Mar
Page Number:41 - 50
DOI: 10.1016/s0048-9697(01)00960-3
ISSN/ISBN:0048-9697 (Print) 0048-9697 (Linking)
Abstract:"We studied four libraries in the University of Modena and Reggio Emilia (Northern Italy) to determine the presence of polluting agents such as total dusts, formaldehyde and other volatile organic compounds (VOCs) including benzene, toluene and xylenes and to assess the sense of well-being perceived by library users. This investigation was suggested by an increase in reported symptoms related to Sick Building Syndrome (SBS) observed in recent decades among people spending most of their time in various indoor environments, including libraries. The microclimatic conditions and the concentrations of pollutants indicated an acceptable situation on the whole, even though a wide range of total dust values (40-350 microg/m3) and total VOCs (203-749 microg/m3) was observed. However, the perception of the different environmental parameters by the 130 library users that were interviewed identified the existence of some discomfort mainly caused by the feeling of poor ventilation. Moreover, 78.5% of the subjects stated they had at least one of the 16 investigated symptoms potentially related to a SBS. The place of occurrence of the self-reported symptoms was also investigated, the symptoms arising during library attendance more frequently than elsewhere were only four, and in particular feeling hot, sore eyes, dry throat and breathing difficulties. Overall, our study has shown the existence of an association between microclimatic perceptions as reported by library users and subjective symptoms related to SBS, considering the four libraries separately, the highest prevalence of self-reported symptoms was found in the library where environmental discomfort as perceived by users was greatest. Nevertheless, an association between subjective self-reported symptoms and both microclimatic conditions as resulted by instrumental measurements and/or pollutants concentrations was not apparent"
Keywords:"Adult Air Pollution, Indoor/*adverse effects Climate Disinfectants/adverse effects Dust Female Formaldehyde/adverse effects *Health Status Humans Libraries Male Organic Chemicals Perception Prevalence Sick Building Syndrome/epidemiology/*etiology Ventilat;"
Notes:"MedlineRighi, E Aggazzotti, G Fantuzzi, G Ciccarese, V Predieri, G eng Netherlands 2002/03/12 Sci Total Environ. 2002 Mar 8; 286(1-3):41-50. doi: 10.1016/s0048-9697(01)00960-3"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024