Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAnalysis of arsenic species in fish after derivatization by GC-MS    Next AbstractDetermination of recovery rates of adsorbents for sampling very volatile organic compounds (C(1)C(6)) in dry and humid air in the sub-ppb range by use of thermal desorption gas chromatography-mass spectrometry »

Indoor Air


Title:Determination of radon exhalation from construction materials using VOC emission test chambers
Author(s):Richter M; Jann O; Kemski J; Schneider U; Krocker C; Hoffmann B;
Address:"Division 4.2 Materials and Air Pollutants, BAM Federal Institute for Materials Research and Testing, Berlin, Germany"
Journal Title:Indoor Air
Year:2013
Volume:20130321
Issue:5
Page Number:397 - 405
DOI: 10.1111/ina.12031
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"The inhalation of (222) Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available measuring devices in combination with VOC emission test chambers. Five materials - two types of clay brick, clinker brick, light-weight concrete brick, and honeycomb brick - generally used for wall constructions were used for the experiments. Their contribution to real room concentrations was estimated by applying room model parameters given in ISO 16000-9, RP 112, and AgBB. This knowledge can be relevant, if for instance indoor radon concentration is limited by law. The test set-up used here is well suited for application in test laboratories dealing with VOC emission testing"
Keywords:Algorithms *Construction Materials Radon/*analysis Volatile Organic Compounds Building material Emission test chamber Indoor Air Quality Radon exhalation Radon measurement Real room radon concentrations;
Notes:"MedlineRichter, M Jann, O Kemski, J Schneider, U Krocker, C Hoffmann, B eng Evaluation Study Research Support, Non-U.S. Gov't England 2013/02/05 Indoor Air. 2013 Oct; 23(5):397-405. doi: 10.1111/ina.12031. Epub 2013 Mar 21"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-09-2024