Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractModels for the adsorption of organic compounds at gas-water interfaces    Next AbstractEvaluation of Resistance to Fescue Toxicosis in Purebred Angus Cattle Utilizing Animal Performance and Cytokine Response »

J Chromatogr A


Title:Evaluation of the separation characteristics of application-specific (volatile organic compounds) open-tubular columns for gas chromatography
Author(s):Poole CF; Qian J; Kiridena W; Dekay C; Koziol WW;
Address:"Department of Chemistry, Wayne State University, Detroit, MI 48202, USA. cfp@chem.wayne.edu"
Journal Title:J Chromatogr A
Year:2006
Volume:20060920
Issue:1-Feb
Page Number:284 - 290
DOI: 10.1016/j.chroma.2006.08.092
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"The solvation parameter model is used to characterize the separation characteristics of two application-specific open-tubular columns (Rtx-Volatiles and Rtx-VGC) and a general purpose column for the separation of volatile organic compounds (DB-WAXetr) at five equally spaced temperatures over the range 60-140 degrees C. System constant differences and retention factor correlation plots are then used to determine selectivity differences between the above columns and their closest neighbors in a large database of system constants and retention factors for forty-four open-tubular columns. The Rtx-Volatiles column is shown to have separation characteristics predicted for a poly(dimethyldiphenylsiloxane) stationary phase containing about 16% diphenylsiloxane monomer. The Rtx-VGC column has separation properties similar to the poly(cyanopropylphenyldimethylsiloxane) stationary phase containing 14% cyanopropylphenylsiloxane monomer DB-1701 for non-polar and dipolar/polarizable compounds but significantly different characteristics for the separation of hydrogen-bond acids. For all practical purposes the DB-WAXetr column is shown to be selectivity equivalent to poly(ethylene glycol) columns prepared using different chemistries for bonding and immobilizing the stationary phase. Principal component analysis and cluster analysis are then used to classify the system constants for the above columns and a sub-database of eleven open-tubular columns (DB-1, HP-5, DB-VRX, Rtx-20, DB-35, Rtx-50, Rtx-65, DB-1301, DB-1701, DB-200, and DB-624) commonly used for the separation of volatile organic compounds. A rationale basis for column selection based on differences in intermolecular interactions is presented as an aid to method development for the separation of volatile organic compounds"
Keywords:"Chromatography, Gas Evaluation Studies as Topic Organic Chemicals/*isolation & purification Polyethylene Glycols/chemistry Siloxanes/chemistry Volatilization;"
Notes:"MedlinePoole, Colin F Qian, Jing Kiridena, Waruna Dekay, Colleen Koziol, Wladyslaw W eng Netherlands 2006/09/26 J Chromatogr A. 2006 Nov 17; 1134(1-2):284-90. doi: 10.1016/j.chroma.2006.08.092. Epub 2006 Sep 20"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024