Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractHigh-Throughput Flavor Analysis and Mapping of Flavor Alterations Induced by Different Genotypes of Mentha by Means of UHPLC-MS/MS    Next AbstractCharacteristics of reproductive organs and estimates of reproductive potential in Scandinavian male grey wolves (Canis lupus) »

Gut


Title:Detection of Barrett's oesophagus through exhaled breath using an electronic nose device
Author(s):Peters Y; Schrauwen RWM; Tan AC; Bogers SK; de Jong B; Siersema PD;
Address:"Gastroenterology and Hepatology, Radboudumc, Nijmegen, Gelderland, The Netherlands. Gastroenterology and Hepatology, Ziekenhuis Bernhoven, Uden, Noord-Brabant, The Netherlands. Canisius Wilhelmina Hospital, Nijmegen, The Netherlands. Gastroenterology and Hepatology, Radboudumc, Nijmegen, Gelderland, The Netherlands peter.siersema@radboudumc.nl"
Journal Title:Gut
Year:2020
Volume:20200225
Issue:7
Page Number:1169 - 1172
DOI: 10.1136/gutjnl-2019-320273
ISSN/ISBN:1468-3288 (Electronic) 0017-5749 (Linking)
Abstract:"Timely detection of oesophageal adenocarcinoma (OAC) and even more so its precursor Barrett's oesophagus (BO) could contribute to decrease OAC incidence and mortality. An accurate, minimally-invasive screening method for BO for widespread use is currently not available. In a proof-of-principle study in 402 patients, we developed and cross-validated a BO prediction model using volatile organic compounds (VOCs) analysis with an electronic nose device. This electronic nose was able to distinguish between patients with and without BO with good diagnostic accuracy (sensitivity 91% specificity 74%) and seemed to be independent of proton pump inhibitor use, the presence of hiatal hernia, and reflux. This technique may enable an efficient, well-tolerated, and sensitive and specific screening method to select high-risk individuals to undergo upper endoscopy"
Keywords:Barrett Esophagus/*diagnosis Breath Tests/instrumentation/*methods Case-Control Studies *Electronic Nose Female Humans Male Middle Aged Reproducibility of Results Sensitivity and Specificity Volatile Organic Compounds/analysis barrett's oesophagus breath;
Notes:"MedlinePeters, Yonne Schrauwen, Ruud W M Tan, Adriaan C Bogers, Sanne K de Jong, Bart Siersema, Peter D eng England 2020/02/27 Gut. 2020 Jul; 69(7):1169-1172. doi: 10.1136/gutjnl-2019-320273. Epub 2020 Feb 25"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024