Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Comparative application of solid-phase microextraction fibre assemblies and semi-permeable membrane devices as passive air samplers for semi-volatile chlorinated organic compounds. A case study on the landfill 'Grube Antonie' in Bitterfeld, Germany"    Next AbstractCo(i)-ordinating defenses: NaCOI1 mediates herbivore- induced resistance in Nicotiana attenuata and reveals the role of herbivore movement in avoiding defenses »

Chemosphere


Title:New passive samplers for chlorinated semivolatile organic pollutants in ambient air
Author(s):Paschke H; Popp P;
Address:"Department of Analytical Chemistry, UFZ--Centre for Environmental Research Leipzig-Halle, Permoserstrasse 15, 04318 Leipzig, Germany"
Journal Title:Chemosphere
Year:2005
Volume:58
Issue:7
Page Number:855 - 863
DOI: 10.1016/j.chemosphere.2004.09.045
ISSN/ISBN:0045-6535 (Print) 0045-6535 (Linking)
Abstract:"Two new types of passive samplers were designed and tested on semivolatile organic compounds. The first type (a spiral-rod sampler) consists of a low-density polyethylene membrane acting as a permeation film and a silicone elastomer as the receiving material; the second (a stir-bar sampler) has the same membrane material but a polydimethylsiloxane-coated stir bar acting as the collector phase and installed radially symmetrically in the sampler. The advantages of the new samplers are their simple design, low costs, and their easy processing via thermodesorption coupled with capillary gas chromatography and mass selective detection. In both samplers, the uptake of selected analytes was integrative over exposure periods of up to 384 h. The sampling rates calculated from a laboratory calibration study using the chlorinated semivolatiles hexachlorobenzene, hexachlorocyclohexane isomers and polychlorinated biphenyls ranged from 88.1 ml h-1 for delta-hexachlorocyclohexane to 3443 ml h-1 for 2,2',5,5'-tetrachlorobiphenyl. A field trial at a hazardous waste dump near Bitterfeld, Germany, for up to 21 days combined with periodical determinations of air concentrations using low-volume sampling indicated that the new samplers can in principle be used in the field, although the sampling rates derived from the field results differed considerably from the laboratory findings. Nevertheless the preliminary results suggest that the new sampler types are promising for the long-term air monitoring of semivolatiles"
Keywords:Air Pollutants/*analysis Calibration Environmental Monitoring/*instrumentation Equipment Design Hydrocarbons/*analysis Volatilization;
Notes:"MedlinePaschke, Heidrun Popp, Peter eng Evaluation Study Research Support, Non-U.S. Gov't England 2005/01/11 Chemosphere. 2005 Feb; 58(7):855-63. doi: 10.1016/j.chemosphere.2004.09.045"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024