Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Chemosensory Transmembrane Protein Families in the Coffee White Stemborer, Xylotrechus quadripes (Coleoptera: Cerambycidae)"    Next AbstractInsecticide resistance reduces the profitability of insect-resistant rice cultivars »

Int J Environ Res Public Health


Title:Experimental Investigation of Air Quality in a Subway Station with Fully Enclosed Platform Screen Doors
Author(s):Pang L; Yang C; Cao X; Tian Q; Li B;
Address:"School of Aeronautic Science and Engineering, Beihang University, Beijing 100191, China. School of Aero-Engine, Shenyang Aerospace University, Shenyang 110136, China. School of Information Science and Technology, North China University of Technology, Beijing 100144, China"
Journal Title:Int J Environ Res Public Health
Year:2020
Volume:20200719
Issue:14
Page Number: -
DOI: 10.3390/ijerph17145213
ISSN/ISBN:1660-4601 (Electronic) 1661-7827 (Print) 1660-4601 (Linking)
Abstract:"In this study, the indoor air quality (IAQ) was investigated in a subway station with fully enclosed platform screen doors in Beijing, China. Eight indoor air pollutants, including PM(2.5), PM(10), SO(2) (sulfur dioxide), NO(2) (nitrogen dioxide), NH(3) (ammonia), CO (carbon monoxide), CH(2)O (formaldehyde) and TVOC (total volatile organic compound), were measured for six consecutive days in October 2019. The results indicated that the IAQ in the subway station was basically stable at good levels for most times during the whole measurement period. All eight indoor air pollutants were far below their corresponding maximum allowable concentrations, except for the PM(2.5) concentrations, which occasionally exceeded the concentration limits. The concentrations of indoor air pollutants in the subway station were basically within the corresponding standards. The correlation analyses showed that outdoor air pollutants have important influences on indoor air pollutants. The concentrations of PM(10), PM(2.5), SO(2), NO(2) and CO in the subway station were positively correlated with their corresponding outdoor concentrations. PM(10) was statistically significantly correlated with the passenger flow and train frequency, but the other air pollutants were less impacted by the passenger flow and train frequency"
Keywords:"*Air Pollutants *Air Pollution, Indoor/analysis Beijing Environmental Monitoring Particulate Matter *Railroads I/O ratio airborne pollutants indoor air quality subway station;"
Notes:"MedlinePang, Liping Yang, Chenyuan Cao, Xiaodong Tian, Qing Li, Bo eng Research Support, Non-U.S. Gov't Switzerland 2020/07/28 Int J Environ Res Public Health. 2020 Jul 19; 17(14):5213. doi: 10.3390/ijerph17145213"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024