Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIdentification of volatile organic compounds in blood by purge and trap PLOT-capillary gas chromatography coupled with Fourier transform infrared spectroscopy    Next AbstractCharacterization of virgin walnut oils and their residual cakes produced from different varieties »

J Anal Toxicol


Title:Identification limits for volatile organic compounds in the blood by purge-and-trap GC-FTIR
Author(s):Ojanpera I; Pihlainen K; Vuori E;
Address:"Department of Forensic Medicine, University of Helsinki, Finland"
Journal Title:J Anal Toxicol
Year:1998
Volume:22
Issue:4
Page Number:290 - 295
DOI: 10.1093/jat/22.4.290
ISSN/ISBN:0146-4760 (Print) 0146-4760 (Linking)
Abstract:"An analysis method for volatile organic compounds in blood based on purge-and-trap extraction coupled with gas chromatography-Fourier transform infrared spectroscopy (GC-FTIR) was developed. The sample volume was 5 mL, and the internal standard was diethyl ketone. The chromatographic separation was carried out on a PoraPLOT Q capillary column, and the effluent was first directed to the FTIR and then to a flame ionization detector (FID). FTIR identification limits were measured for 27 volatile organic compounds; the criteria for the limit were that the first hit-list position should be obtained against the Sadtler library, which contains 3240 spectra, and that the correlation value should exceed 0.5. It was required that the peak be seen by FID but not necessarily by a Gram-Schmidt chromatogram. The FTIR identification limits, ranging from 0.01 mg/L for ethyl acetate, methylethyl ketone, and sevoflurane to 24 mg/L for methanol, generally allowed the detection of volatile-substance exposure at a lower level than is acutely toxic. Quantitative calibration data were presented for selected substances, based on the FID response, which shows that the method is also amenable to quantitative analysis. The throughput of the method without additional automation is five samples per day, the purge-and-trap stage being the limiting factor"
Keywords:"Flame Ionization/*methods Humans Organic Chemicals/*blood Poisons/analysis Reference Values Sensitivity and Specificity Spectroscopy, Fourier Transform Infrared;"
Notes:"MedlineOjanpera, I Pihlainen, K Vuori, E eng England 1998/07/29 J Anal Toxicol. 1998 Jul-Aug; 22(4):290-5. doi: 10.1093/jat/22.4.290"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024