Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEndogenous fatty acids in olfactory hairs influence pheromone binding protein structure and function in Lymantria dispar    Next AbstractExhaled breath analysis for the early detection of lung cancer: recent developments and future prospects »

J Thorac Oncol


Title:Exhaled Breath Analysis for Monitoring Response to Treatment in Advanced Lung Cancer
Author(s):Nardi-Agmon I; Abud-Hawa M; Liran O; Gai-Mor N; Ilouze M; Onn A; Bar J; Shlomi D; Haick H; Peled N;
Address:"Thoracic Cancer Research and Detection Center, Sheba Medical Center, Tel-Aviv, Israel. Department of Chemical Engineering, Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel. Thoracic Cancer Unit, Davidoff Cancer Center, Rabin Medical Center, Israel. Thoracic Oncology Unit, Institute of Oncology, Sheba Medical Center, Tel-Aviv, Israel. Thoracic Oncology Unit, Institute of Oncology, Sheba Medical Center, Tel-Aviv, Israel. Electronic address: hhossam@technion.ac.il. Thoracic Cancer Research and Detection Center, Sheba Medical Center, Tel-Aviv, Israel; Thoracic Cancer Unit, Davidoff Cancer Center, Rabin Medical Center, Israel"
Journal Title:J Thorac Oncol
Year:2016
Volume:20160309
Issue:6
Page Number:827 - 837
DOI: 10.1016/j.jtho.2016.02.017
ISSN/ISBN:1556-1380 (Electronic) 1556-0864 (Linking)
Abstract:"INTRODUCTION: The Response Evaluation Criteria in Solid Tumors (RECIST) serve as the accepted standard to monitor treatment efficacy in lung cancer. However, the time intervals between consecutive computerized tomography scans might be too long to allow early identification of treatment failure. This study examines the use of breath sampling to monitor responses to anticancer treatments in patients with advanced lung cancer. METHODS: A total of 143 breath samples were collected from 39 patients with advanced lung cancer. The exhaled breath signature, determined by gas chromatography/mass spectrometry and a nanomaterial-based array of sensors, was correlated with the response to therapy assessed by RECIST: complete response, partial response, stable disease, or progressive disease. RESULTS: Gas chromatography/mass spectrometry analysis identified three volatile organic compounds as significantly indicating disease control (PR/stable disease), with one of them also significantly discriminating PR/stable disease from progressive disease. The nanoarray had the ability to monitor changes in tumor response across therapy, also indicating any lack of further response to therapy. When one-sensor analysis was used, 59% of the follow-up samples were identified correctly. There was 85% success in monitoring disease control (stable disease/partial response). CONCLUSION: Breath analysis, using mainly the nanoarray, may serve as a surrogate marker for the response to systemic therapy in lung cancer. As a monitoring tool, it can provide the oncologist with a quick bedside method of identifying a lack of response to an anticancer treatment. This may allow quicker recognition than does the current RECIST analysis. Early recognition of treatment failure could improve patient care"
Keywords:"Adenocarcinoma/metabolism/*pathology/therapy Adult Aged Aged, 80 and over Biomarkers, Tumor/*analysis *Breath Tests Carcinoma, Non-Small-Cell Lung/metabolism/*pathology/therapy Carcinoma, Squamous Cell/metabolism/*pathology/therapy Combined Modality Thera;"
Notes:"MedlineNardi-Agmon, Inbar Abud-Hawa, Manal Liran, Ori Gai-Mor, Naomi Ilouze, Maya Onn, Amir Bar, Jair Shlomi, Dekel Haick, Hossam Peled, Nir eng Research Support, Non-U.S. Gov't 2016/03/13 J Thorac Oncol. 2016 Jun; 11(6):827-37. doi: 10.1016/j.jtho.2016.02.017. Epub 2016 Mar 9"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-09-2024