Indoor Air


Title:Dermal uptake directly from air under transient conditions: advances in modeling and comparisons with experimental results for human subjects
Author(s):Morrison GC; Weschler CJ; Beko G;
Address:"Civil, Architectural and Environmental Engineering, Missouri University of Science and Technology, Rolla, MO, USA. Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ, USA. Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark"
Journal Title:Indoor Air
Year:2016
Volume:20160122
Issue:6
Page Number:913 - 924
DOI: 10.1111/ina.12277
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"To better understand the dermal exposure pathway, we enhance an existing mechanistic model of transdermal uptake by including skin surface lipids (SSL) and consider the impact of clothing. Addition of SSL increases the overall resistance to uptake of SVOCs from air but also allows for rapid transfer of SVOCs to sinks like clothing or clean air. We test the model by simulating di-ethyl phthalate (DEP) and di-n-butyl phthalate (DnBP) exposures of six bare-skinned (Weschler et al. 2015, Environ. Health Perspect., 123, 928) and one clothed participant (Morrison et al. 2016, J. Expo. Sci. Environ. Epidemiol., 26, 113). The model predicts total uptake values that are consistent with the measured values. For bare-skinned participants, the model predicts a normalized mass uptake of DEP of 3.1 (mug/m(2) )/(mug/m(3) ), whereas the experimental results range from 1.0 to 4.3 (mug/m(2) )/(mug/m(3) ); uptake of DnBP is somewhat overpredicted: 4.6 (mug/m(2) )/(mug/m(3) ) vs. the experimental range of 0.5-3.2 (mug/m(2) )/(mug/m(3) ). For the clothed participant, the model predicts higher than observed uptake for both species. Uncertainty in model inputs, including convective mass transfer coefficients, partition coefficients, and diffusion coefficients, could account for overpredictions. Simulations that include transfer of skin oil to clothing improve model predictions. A dynamic model that includes SSL is more sensitive to changes that impact external mass transfer such as putting on and removing clothes and bathing"
Keywords:"Adult Air Pollution, Indoor/*analysis *Clothing Environmental Monitoring Female Humans Male Phthalic Acids/analysis/pharmacokinetics Research Subjects *Skin Absorption Volatile Organic Compounds/*analysis/pharmacokinetics Clothing Dermal uptake Exposure m;"
Notes:"MedlineMorrison, G C Weschler, C J Beko, G eng Research Support, Non-U.S. Gov't England 2016/01/01 Indoor Air. 2016 Dec; 26(6):913-924. doi: 10.1111/ina.12277. Epub 2016 Jan 22"

 