Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractImplementation of Recycling Cigarette Butts in Lightweight Bricks and a Proposal for Ending the Littering of Cigarette Butts in Our Cities    Next AbstractBiofiltration technology for the removal of toluene from polluted air using Streptomyces griseus »

J AOAC Int


Title:Flame atomic absorption determination of trace amounts of cadmium after preconcentration using a thiol-containing task-specific ionic liquid
Author(s):Mohamadi M; Mostafavi A;
Address:"Shahid Bahonar University of Kerman, Department of Chemistry, PO Box 76175-133, Kerman, Iran. m.mohamadi794@gmail.com"
Journal Title:J AOAC Int
Year:2011
Volume:94
Issue:3
Page Number:959 - 967
DOI:
ISSN/ISBN:1060-3271 (Print) 1060-3271 (Linking)
Abstract:"Dispersive liquid-liquid microextraction (DLLME) based on a task-specific ionic liquid (TSIL) was developed for the extraction and preconcentration of trace amounts of cadmium from aqueous samples, followed by flame atomic absorption spectrometry (FAAS) determination. In the proposed approach, cadmium ions are extracted from aqueous samples using small volumes of trioctylmethylammonium thiosalicylate (TOMATS) dissolved in acetone. TOMATS is a thiol-containing TSIL that can form metal thiolate complexes due to the chelating effect of the ortho-positioned carboxylate group relative to the thiol functionality. The main parameters affecting the performance of DLLME based on TSIL, such as pH, amount of TOMATS, extraction time, injection volume, salt addition, and centrifugation time, were optimized. Under optimum conditions, an LOD of 1.16 ng/mL and a good RSD of 1.8% at 60.0 ng/mL were obtained (n=7). The proposed method was applied to tap water, wastewater, well water, and milk samples. The results showed that DLLME based on TSIL combined with FAAS is a rapid, simple, sensitive, selective, low cost, volatile organic solvent-free, and efficient analytical method for the separation and determination of trace amounts of cadmium ions"
Keywords:"Anthraquinones Cadmium/*chemistry Environmental Pollutants/*chemistry Hydrogen-Ion Concentration Ionic Liquids/*chemistry Ions Molecular Structure Salts Spectrophotometry, Atomic/*methods Sulfhydryl Compounds/*chemistry Time Factors;"
Notes:"MedlineMohamadi, Maryam Mostafavi, Ali eng England 2011/07/30 J AOAC Int. 2011 May-Jun; 94(3):959-67"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 23-09-2024