Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMK-801 and male odours induce c-fos expression in the AOB of juvenile female mice    Next AbstractAnaerobic biodegradation of dissolved ethanol in a pilot-scale sand aquifer: Gas phase dynamics »

Int J Occup Environ Health


Title:Exposure assessment of non-electric ice resurfacer operators in indoor ice rinks: a pilot study
Author(s):McLennon T; Hon CY;
Address:"a School of Occupational and Public Health , Ryerson University , Toronto , Canada"
Journal Title:Int J Occup Environ Health
Year:2017
Volume:20180502
Issue:3
Page Number:228 - 233
DOI: 10.1080/10773525.2018.1468130
ISSN/ISBN:2049-3967 (Electronic) 1077-3525 (Print) 1077-3525 (Linking)
Abstract:"Exposure of ice resurfacer operators to indoor air contaminants was measured in six indoor ice arenas. A standardized questionnaire on technical and operational features was employed and indoor airborne concentrations of carbon monoxide (CO), carbon dioxide (CO(2)), nitric oxide (NO), nitrogen dioxide (NO(2)), sulfur dioxide (SO(2)), and total volatile organic compounds (VOCs) were measured. Air samples were collected using a range of direct reading instruments attached to the driver's seat of the resurfacer. The range of mean exposure concentrations via positional sampling (i.e. as close as able to the operator's breathing zone) were 5.7-7.4 ppm, 694-2171 ppm, <0.5 to 0.5 ppm, and < 0.1 to 0.2 ppm, for CO, CO(2), NO, and NO(2), respectively. Exposure levels for SO(2) and VOC were below detection. Overall, each of the measured indoor air contaminants was found to be below its respective occupational exposure limits (OEL), suggesting that the risk of hazardous exposure is low. The use of natural gas as a fuel source is believed to contribute to low contaminant concentrations"
Keywords:"Air Pollutants/*analysis Air Pollution, Indoor/*analysis Humans Ice Occupational Exposure/*analysis Ontario Pilot Projects *Skating Occupational exposure combustion byproducts ice rinks indoor air quality non-electric ice resurfacer;"
Notes:"MedlineMcLennon, Travis Hon, Chun-Yip eng Research Support, Non-U.S. Gov't England 2018/05/03 Int J Occup Environ Health. 2017 Jul; 23(3):228-233. doi: 10.1080/10773525.2018.1468130. Epub 2018 May 2"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 21-09-2024