Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCarbonic anhydrase IV in lizard chemical signals    Next AbstractDiagnostic potential of the pulsed discharged helium ionization detector (PDHID) for pathogenic Mycobacterial volatile biomarkers »

Rev Sci Instrum


Title:Invited article: A materials investigation of a phase-change micro-valve for greenhouse gas collection and other potential applications
Author(s):Manginell RP; Moorman MW; Rejent JA; Vianco PT; Grazier MJ; Wroblewski BD; Mowry CD; Achyuthan KE;
Address:"Microsystems-Enabled Detection Department, Sandia National Laboratories, Albuquerque, New Mexico 87185, USA"
Journal Title:Rev Sci Instrum
Year:2012
Volume:83
Issue:3
Page Number:31301 -
DOI: 10.1063/1.3688856
ISSN/ISBN:1089-7623 (Electronic) 0034-6748 (Linking)
Abstract:"The deleterious consequences of climate change are well documented. Future climate treaties might mandate greenhouse gas (GHG) emissions measurement from signatories in order to verify compliance. The acquisition of atmospheric chemistry would benefit from low cost, small size/weight/power of microsystems. In this paper, we investigated several key materials science aspects of a phase-change microvalve (PCmuV) technology with low power/size/weight/cost for ubiquitous GHG sampling. The novel design, based on phase-change material low-melting-point eutectic metal alloys (indium-bismuth, InBi and tin-lead, SnPb), could be actuated at temperatures as low as 72 degrees C. Valve manufacturing was based on standard thick and thin-film processes and solder technologies that are commonly used in industry, enabling low-cost, high-volume fabrication. Aging studies showed that it was feasible to batch fabricate the PCmuVs and store them for future use, especially in the case of SnPb alloys. Hermetic sealing of the valve prototypes was demonstrated through helium leak testing, and Mil spec leak rates less than 1 x 10(-9) atm cm(3)/s were achieved. This confirms that the sample capture and analysis interval can be greatly expanded, easing the logistical burdens of ubiquitous GHG monitoring. Highly conservative and hypothetical CO(2) bias due to valve actuation at altitude in 1 cm(3) microsamplers would be significantly below 1.0 and 2.2 ppmv for heat-treated InBi and SnPb solders, respectively. The CO(2) bias from the PCmuV scales well, as a doubling of sampler volume halved the bias. We estimated the shelf life of the SnPb PCmuVs to be at least 2.8 years. These efforts will enable the development of low cost, low dead volume, small size/weight microsystems for monitoring GHGs and volatile organic compounds"
Keywords:
Notes:"PubMed-not-MEDLINEManginell, Ronald P Moorman, Matthew W Rejent, Jerome A Vianco, Paul T Grazier, Mark J Wroblewski, Brian D Mowry, Curtis D Achyuthan, Komandoor E eng 2012/04/03 Rev Sci Instrum. 2012 Mar; 83(3):031301. doi: 10.1063/1.3688856"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 18-06-2024