Title:Determination of volatile organic compounds in contaminated air using semipermeable membrane devices
Author(s):Ly-Verdu S; Esteve-Turrillas FA; Pastor A; de la Guardia M;
Address:"Analytical Chemistry Department, University of Valencia, Edifici Jeroni Munoz, 50 Dr Moliner, 46100 Burjassot, Valencia, Spain"
Journal Title:Talanta
Year:2010
Volume:20091110
Issue:5
Page Number:2041 - 2048
DOI: 10.1016/j.talanta.2009.11.001
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"Semipermeable membrane devices (SPMDs) were evaluated as passive samplers for the determination of 26 volatile organic compounds (VOCs) in contaminated air of occupational environments. A direct methodology based on the use of head-space-gas chromatography-mass spectrometry (HS-GC-MS) was developed for VOCs determinations in SPMDs, without any sample pre-treatment and avoiding the use of solvents. A desorption temperature of 150 degrees C for 10 min was sufficient for a sensitive VOCs determination providing limits of detection in the range of 15 ng SPMD(-1) for 21 of 26 studied compounds. Linear and equilibrium uptake models were established for each VOC from compound isotherms. Highly volatile compounds were slightly absorbed and moderately volatile compounds were strongly absorbed by SPMDs. This study is the first precedent of the use of SPMDs for the simultaneous sampling of a wide number of VOCs. The use of SPMDs is a simple and low cost alternative to ordinary sampling devices such as Radiello diffusive samplers or badge-type solid-phase supports"
Keywords:"Air Pollutants/*analysis Environmental Monitoring/*instrumentation/methods Gas Chromatography-Mass Spectrometry/methods Limit of Detection *Membranes, Artificial Volatile Organic Compounds/*analysis;"
Notes:"MedlineLy-Verdu, Saray Esteve-Turrillas, Francesc A Pastor, Agustin de la Guardia, Miguel eng Evaluation Study Research Support, Non-U.S. Gov't Netherlands 2010/02/16 Talanta. 2010 Mar 15; 80(5):2041-8. doi: 10.1016/j.talanta.2009.11.001. Epub 2009 Nov 10"

 