Int J Environ Res Public Health


Title:Adsorption Characteristics of Activated Carbon Fibers in Respirator Cartridges for Toluene
Author(s):Balanay JAG; Oh J;
Address:"Environmental Health Sciences Program, Department of Health Education and Promotion, College of Health and Human Performance, East Carolina University, Greenville, NC 27858, USA. Department of Environmental Health Sciences, School of Public Health, University of Alabama at Birmingham, Birmingham, AL 35233, USA"
Journal Title:Int J Environ Res Public Health
Year:2021
Volume:20210812
Issue:16
Page Number: -
DOI: 10.3390/ijerph18168505
ISSN/ISBN:1660-4601 (Electronic) 1661-7827 (Print) 1660-4601 (Linking)
Abstract:"Respirator use has been shown to be associated with overall discomfort. Activated carbon fiber (ACF) has potential as an alternative adsorbent for developing thinner, lightweight, and efficient respirators due to its larger surface area, microporosity, and fabric form. The purpose of this pilot study was to determine the adsorption characteristics of commercially available ACF in respirator cartridges with varying ACF composition for toluene protection. Seven ACF types (one cloth, six felt) with varying properties were tested. Seven ACF cartridge configurations with varying ACF composition were challenged with five toluene concentrations (20-500 ppm) at constant air temperature (23 degrees C), relative humidity (50%), and air flow (32 LPM). Breakthrough curves were obtained using photoionization detectors. Breakthrough times (10%, 50%, and 5 ppm) and adsorption capacities were compared among ACF cartridge configurations to determine their suitable application in respiratory protection. Results showed that ACF cartridges containing the densest ACF felt types had the longest average breakthrough times (e.g., ~250-270 min to reach 5 ppm breakthrough time) and those containing ACF felt types with the highest specific surface areas had the highest average adsorption capacity (~450-470 mg/g). The ACF cartridges demonstrated breakthrough times of <1 h for 500 ppm toluene and 8-16 h for 20 ppm toluene. The ACF cartridges are more reliable for use at low ambient toluene concentrations but still have potential for use at higher concentrations for short-term protection. ACF felt forms with appropriate properties (density of ~0.07 g/cm(3); specific surface area of ~2000 m(2)/g) have shown promising potential for the development of lighter and thinner respirators for protection against toluene"
Keywords:"Adsorption Carbon Fiber Charcoal Pilot Projects *Respiratory Protective Devices *Toluene Ventilators, Mechanical activated carbon fiber breakthrough respiratory protection service life toluene volatile organic compound;"
Notes:"MedlineBalanay, Jo Anne G Oh, Jonghwa eng Research Support, U.S. Gov't, P.H.S. Switzerland 2021/08/28 Int J Environ Res Public Health. 2021 Aug 12; 18(16):8505. doi: 10.3390/ijerph18168505"

 