Indoor Air


Title:Achieving 'excellent' indoor air quality in commercial offices equipped with air-handling unit--respirable suspended particulate
Author(s):Lam KS; Chan FS; Fung WY; Lui BS; Lau LW;
Address:"Department of Civil and Structural Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong. cekslam@polyu.edu.hk"
Journal Title:Indoor Air
Year:2006
Volume:16
Issue:2
Page Number:86 - 97
DOI: 10.1111/j.1600-0668.2005.00409.x
ISSN/ISBN:0905-6947 (Print) 0905-6947 (Linking)
Abstract:"A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficiency particulates air (HEPA) filters were tested in a commercial building in Causeway Bay. The results show that an RSP objective of <20 microg/m3 could be met by removing RSP from both the return air and outdoor air supply simultaneously. This level of performance is classed as 'excellent' by the Hong Kong Government, Environmental Protection Department. Filters with efficiency that exceed 80% placed both in the return air and outdoor air were sufficient to meet the objective. It is not necessary to install HEPA filters to achieve the 'excellent' class. The outdoor air filter has great influence on the steady state indoor RSP concentration while the effective cleaning rate is governed by the return air filter. Higher efficiency filters increased the static drop but the volume flow of the air fan was not affected significantly. The additional cost incurred was <5% of the existing operation cost. PRACTICAL IMPLICATIONS: This paper reports a field study of RSP control for an indoor office environment. The results are directly applicable to building service engineering in the design of ventilation systems using air-handling units. Field observations indicated that indoor RSP in an office environment could be suppressed below 20 microg/m3 within 1 h by the simultaneous filtration of outdoor air and return air. Outdoor air filtration has a great influence on the steady state indoor concentration and return air filtration governs the cleaning rate. It is believed that the results of this study could be extended to the cleaning of other indoor pollutants such as volatile organic compounds"
Keywords:"Air Movements Air Pollution, Indoor/analysis/*prevention & control Filtration/methods Hong Kong *Ventilation Workplace;"
Notes:"MedlineLam, K S Chan, F S Fung, W Y Lui, B S S Lau, L W L eng Comparative Study Research Support, Non-U.S. Gov't England 2006/03/02 Indoor Air. 2006 Apr; 16(2):86-97. doi: 10.1111/j.1600-0668.2005.00409.x"

 