Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEdge effects in the directionally biased distribution of Choristoneura rosaceana (Lepidoptera: Tortricidae) in apple orchards    Next Abstract"Ambient VOCs in residential areas near a large-scale petrochemical complex: Spatiotemporal variation, source apportionment and health risk" »

J Dent Sci


Title:Air quality in a hospital dental department
Author(s):Hsu CT; Hsu SC; Huang SK; Lee CL; Shieh YS;
Address:"Department of Dentistry, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan. Emergency Department, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan. Department of Emergency Medicine, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan. National Institute of Environmental Health Sciences, National Health Research Institutes, Miaoli County, Taiwan. Department of Marine Environment and Engineering, National Sun Yat-sen University, Kaohsiung, Taiwan. Department of Public Health, Kaohsiung Medical University, Kaohsiung, Taiwan. Department of Applied Chemistry, Providence University, Taichung, Taiwan. Department of Biochemistry, National Defense Medical Center, Taipei, Taiwan"
Journal Title:J Dent Sci
Year:2022
Volume:20220407
Issue:3
Page Number:1350 - 1355
DOI: 10.1016/j.jds.2022.03.011
ISSN/ISBN:2213-8862 (Electronic) 1991-7902 (Print) 1991-7902 (Linking)
Abstract:"BACKGROUND/PURPOSE: Documented studies demonstrated that particulate matter 2.5 (PM2.5) are relatively high in dental clinics. However, the PM2.5 composition is unclear. This study aimed to evaluate the dental department's air quality in a teaching hospital. MATERIALS AND METHODS: The SKC AirChek XR5000 pumps and canister samplers were used to collect PM2.5 and volatile organic compounds (VOCs). The PM2.5 composition analysis (polycyclic aromatic hydrocarbons (PAHs) and metals) was conducted, and in the dental clinic and waiting room, the air quality comparison was investigated. Moreover, the dental clinic's air quality was compared before and after air purifier use. RESULTS: In the dental clinic and waiting room, the results revealed high PM2.5 concentration exceeding the standard of the United States Environmental Protection Agency (USEPA) (35 mug/m(3)); the values were 41.08-108.23 mug/m(3) and 17.89-62.72 mug/m(3), respectively. In both investigated locations, VOCs had no significant difference. Among 16 priority PAHs, the result indicated high level of benzo(b)fluoranthene (B(b)f), benzo(k)fluoranthene (B(k)f), benzo(a)pyrene (B(a)p), and indenopyrene (IP). B(b)f and B(k)f and lead (Pb) concentrations were detected with a significant difference in the clinic as compared to the waiting room. In addition, after air purifier use, the B(b)f concentration in the dental clinic reduced from 0.08 to 0.42 ug/m(3) to 0.06-0.18 ug/m(3) (P < 0.05). CONCLUSION: For dental practitioners, an appropriated air quality regulation needs to be considered, due to high air pollutant concentration. In addition, using air purifier can efficiently reduce air pollutants"
Keywords:Dental clinic Pm2.5 Polycyclic aromatic hydrocarbons Volatile organic compounds;
Notes:"PubMed-not-MEDLINEHsu, Chien-Tien Hsu, Shih-Chang Huang, Shau-Ku Lee, Chon-Lin Shieh, Yi-Shing eng Netherlands 2022/07/06 J Dent Sci. 2022 Jul; 17(3):1350-1355. doi: 10.1016/j.jds.2022.03.011. Epub 2022 Apr 7"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024