Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDetection of methyl salicylate using bi-enzyme electrochemical sensor consisting salicylate hydroxylase and tyrosinase    Next AbstractEngineering the Nucleophilic Active Oxygen Species in CuTiO(x) for Efficient Low-Temperature Propene Combustion »

Biosens Bioelectron


Title:A novel bi-enzyme electrochemical biosensor for selective and sensitive determination of methyl salicylate
Author(s):Fang Y; Umasankar Y; Ramasamy RP;
Address:"Nano Electrochemistry Laboratory, College of Engineering, University of Georgia, Athens, GA 30602, United States. Nano Electrochemistry Laboratory, College of Engineering, University of Georgia, Athens, GA 30602, United States. Electronic address: rama@uga.edu"
Journal Title:Biosens Bioelectron
Year:2016
Volume:20160217
Issue:
Page Number:39 - 45
DOI: 10.1016/j.bios.2016.01.095
ISSN/ISBN:1873-4235 (Electronic) 0956-5663 (Linking)
Abstract:"An amperometric sensor based on a bi-enzyme modified electrode was fabricated to detect methyl salicylate, a volatile organic compound released by pathogen-infected plants via systemic response. The detection is based on cascadic conversion reactions that result in an amperometric electrochemical signal. The bi-enzyme electrode is made of alcohol oxidase and horseradish peroxidase enzymes immobilized on to a carbon nanotube matrix through a molecular tethering method. Methyl salicylate undergoes hydrolysis to form methanol, which is consumed by alcohol oxidase to form formaldehyde while simultaneously reducing oxygen to hydrogen peroxide. The hydrogen peroxide will be further reduced to water by horseradish peroxidase, which results in an amperometric signal via direct electron transfer. The bi-enzyme biosensor was evaluated by cyclic voltammetry and constant potential amperometry using hydrolyzed methyl salicylate as the analyte. The sensitivity of the bi-enzyme biosensor as determined by cyclic voltammetry and constant potential amperometry were 112.37 and 282.82muAcm(-2)mM(-1) respectively, and the corresponding limits of detection were 22.95 and 0.98muM respectively. Constant potential amperometry was also used to evaluate durability, repeatability and interference from other compounds. Wintergreen oil was used for real sample study to establish the application of the bi-enzyme sensor for selective determination of plant pathogen infections"
Keywords:"Alcohol Oxidoreductases/chemistry Biosensing Techniques/*methods Electrochemical Techniques/methods Electrodes Enzymes, Immobilized/chemistry Equipment Design Horseradish Peroxidase/chemistry Hydrogen Peroxide/chemistry Hydrolysis Nanotubes, Carbon Oils, ;"
Notes:"MedlineFang, Yi Umasankar, Yogeswaran Ramasamy, Ramaraja P eng Research Support, Non-U.S. Gov't England 2016/02/27 Biosens Bioelectron. 2016 Jul 15; 81:39-45. doi: 10.1016/j.bios.2016.01.095. Epub 2016 Feb 17"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024