J Environ Monit


Title:How to improve reliability in groundwater analysis: over a decade of experience with external quality control in field campaigns on volatile halogenated compounds
Author(s):Dorgerloh U; Becker R; Lutz A; Bremser W; Hilbert S; Nehls I;
Address:"BAM Federal Institute for Materials Research and Testing, Richard-Willstatter-Strasse 11, 12489 Berlin, Germany. ute.dorgerloh@bam.de"
Journal Title:J Environ Monit
Year:2012
Volume:20111128
Issue:1
Page Number:217 - 223
DOI: 10.1039/c1em10460h
ISSN/ISBN:1464-0333 (Electronic) 1464-0325 (Linking)
Abstract:"The reliability in measurement results obtained during environmental monitoring is crucial for the assessment and further planning of remediation efforts on the respective contaminated sites by the responsible authorities. A case study concerned with groundwater contaminated with perchloroethylene, trichloroethylene and 1,1,2-trichlorotrifluoroethane including their degradation products which involves private contract laboratories and an independent provider of quality assurance (QA) is presented. The experience gained with biannual monitoring campaigns over 14 years indicates that the selection of contractors on basis of accreditation status and successful performance in interlaboratory comparisons are not sufficient. Rather the auditing of the contractors by the QA provider prior to each campaign and the crosschecking of selected monitoring samples by the QA provider led to a lasting improvement of reliability in the contractors' measurement results. A mean deviation of 20% from the reference value determined by the QA provider for the crosschecked samples was reached"
Keywords:"Chlorofluorocarbons, Ethane Chlorofluorocarbons, Methane/analysis Environmental Monitoring/*methods Groundwater/*chemistry Halogenation Quality Control Tetrachloroethylene/analysis Trichloroethylene/analysis Volatile Organic Compounds/*analysis Water Poll;"
Notes:"MedlineDorgerloh, Ute Becker, Roland Lutz, Axel Bremser, Wolfram Hilbert, Sabine Nehls, Irene eng Research Support, Non-U.S. Gov't England 2011/11/30 J Environ Monit. 2012 Jan; 14(1):217-23. doi: 10.1039/c1em10460h. Epub 2011 Nov 28"

 