Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractResponses of PM(2.5) and O(3) concentrations to changes of meteorology and emissions in China    Next AbstractSelection on olfactory response to semiochemicals from a plant-host complex in a parasitic wasp »

J Chromatogr A


Title:Purge-and-trap ion chromatography for the determination of trace ammonium ion in high-salinity water samples
Author(s):Wang PY; Wu JY; Chen HJ; Lin TY; Wu CH;
Address:"Environmental Chemistry Laboratory, Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan"
Journal Title:J Chromatogr A
Year:2008
Volume:20080220
Issue:2
Page Number:69 - 74
DOI: 10.1016/j.chroma.2008.02.051
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"It has always been assumed that purge-and-trap (P&T) method is only used for the analysis of volatile organic compounds (VOCs) in aqueous samples. In this paper, a novel P&T preconcentrator has been developed for the determination of trace amounts of ammonium ion in high-salinity water samples by ion chromatography (IC). Method performance is evaluated as a function of concentration of assistant purging material, purging time, and flow rate. Under the optimum P&T conditions with the purified nitrogen gas at flow rate 40 mL/min for 15.0 min at 40 degrees C, the overall collection efficiency is independent of the concentration of ammonium over the range 1.2-5.9 microM. The enrichment factor (EF) of ammonium correlates the ratio of the sample volume to the acceptor solution volume in the trap vessel, providing potentially unlimited increase of the ammonium signal. Our results indicate that environmental samples with low levels of ammonium in matrices with high concentrations of sodium can be easily analyzed and the detection limit down to 75 nM (1.35 ppb) level, corresponding to picomole of ammonia in the injected sample. Calibration graph was constructed with ammonium standards ranging from 0.05 to 6.0 microM and the linearity of the present method was good as suggested by the square of correlation coefficients being better than 0.997. Thus, we have demonstrated that the P&T-IC method allows the routine determination of ammonium ion in seawater samples without cation interferences"
Keywords:Chromatography/*methods Gases/chemistry Quaternary Ammonium Compounds/*analysis *Salinity Seawater/*chemistry Sodium Hydroxide/chemistry Solutions Time Factors Water/*chemistry;
Notes:"MedlineWang, Po-Yen Wu, Jing-Yi Chen, Hung-Jhen Lin, Tzung-Yi Wu, Chien-Hou eng Research Support, Non-U.S. Gov't Netherlands 2008/03/04 J Chromatogr A. 2008 Apr 25; 1188(2):69-74. doi: 10.1016/j.chroma.2008.02.051. Epub 2008 Feb 20"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024