« Previous AbstractLaboratory scale evaluation of volatile organic compound emissions as indication of swine carcass degradation inside biosecure composting units    Next Abstract"Health risk assessment of occupational exposure to hazardous volatile organic compounds in swine gestation, farrowing and nursery barns" »

Bioresour Technol


Title:Air sampling methods for VOCs related to field-scale biosecure swine mortality composting
Author(s):Akdeniz N; Koziel JA; Glanville TD; Ahn H; Crawford BP;
Address:"Department of Agricultural and Biosystems Engineering, Iowa State University, Ames, IA 50011, USA"
Journal Title:Bioresour Technol
Year:2011
Volume:20101025
Issue:3
Page Number:3599 - 3602
DOI: 10.1016/j.biortech.2010.10.100
ISSN/ISBN:1873-2976 (Electronic) 0960-8524 (Linking)
Abstract:"Monitoring specific volatile organic compounds (VOCs) as markers of biosecure carcass degradation is a promising method to test progress and completion of the composting process. The objective of this study was to test the feasibility of using existing aeration ducts in composting units as practical sampling locations. The secondary objective was to test the feasibility of using marker VOC concentrations in aeration ducts to elucidate information about airflow patterns inside composting units. Marker VOC concentrations were significantly higher in the upper aeration duct and this duct can typically be used to collect air samples instead of placing special air sampling probes inside the composting units. Occasionally, the airflow direction inside composting units can change. Marker VOC concentrations can be used to decide the airflow direction inside the composting units. In this study, higher VOC concentrations were measured from the upper aeration duct, and this duct was shown to be an outlet"
Keywords:Animals Environmental Monitoring/*instrumentation Equipment Design Equipment Failure Analysis *Postmortem Changes Soil/*analysis/*chemistry *Swine Volatile Organic Compounds/*analysis;