J Chromatogr A


Title:Optimal experimental designs for estimating Henry's law constants via the method of phase ratio variation
Author(s):Kapelner A; Krieger A; Blanford WJ;
Address:"Department of Mathematics, Queens College, The City University of New York, 65-30 Kissena Blvd., Kiely Hall Suite 605, Flushing, NY 11367, United States. Electronic address: kapelner@qc.cuny.edu. Department of Statistics, The Wharton School of the University of Pennsylvania, 3730 Walnut St, Jon M. Huntsman Hall Suite 442, Philadelphia, PA 19104, United States. Electronic address: krieger@wharton.upenn.edu. School of Earth and Environmental Sciences, Queens College, The City University of New York, 65-30 Kissena Blvd., Science Building Suite D202, Flushing, NY 11367, United States. Electronic address: william.blanford@qc.cuny.edu"
Journal Title:J Chromatogr A
Year:2016
Volume:20160827
Issue:
Page Number:183 - 191
DOI: 10.1016/j.chroma.2016.08.049
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"When measuring Henry's law constants (k(H)) using the phase ratio variation (PRV) method via headspace gas chromatography (G(C)), the value of k(H) of the compound under investigation is calculated from the ratio of the slope to the intercept of a linear regression of the inverse G(C) response versus the ratio of gas to liquid volumes of a series of vials drawn from the same parent solution. Thus, an experimenter collects measurements consisting of the independent variable (the gas/liquid volume ratio) and dependent variable (the G(C)(-1) peak area). A review of the literature found that the common design is a simple uniform spacing of liquid volumes. We present an optimal experimental design which estimates k(H) with minimum error and provides multiple means for building confidence intervals for such estimates. We illustrate performance improvements of our design with an example measuring the k(H) for Naphthalene in aqueous solution as well as simulations on previous studies. Our designs are most applicable after a trial run defines the linear G(C) response and the linear phase ratio to the G(C)(-1) region (where the PRV method is suitable) after which a practitioner can collect measurements in bulk. The designs can be easily computed using our open source software optDesignSlopeInt, an R package on CRAN"
Keywords:"Algorithms Chromatography, Gas/*methods Naphthalenes/analysis Research Design Temperature Water/chemistry Headspace gas chromatography Henry's coefficient Henry's law constant Linear regression Optimal experimental design Phase ratio variation method Slop;"
Notes:"MedlineKapelner, Adam Krieger, Abba Blanford, William J eng Netherlands 2016/09/20 J Chromatogr A. 2016 Oct 14; 1468:183-191. doi: 10.1016/j.chroma.2016.08.049. Epub 2016 Aug 27"

 