« Previous AbstractThe seminal odorant binding protein Obp56g is required for mating plug formation and male fertility in Drosophila melanogaster    Next AbstractRelationships between socioeconomic and lifestyle factors and indoor air quality in French dwellings »

Indoor Air


Title:"Volatile organic pollutants in new and established buildings in Melbourne, Australia"
Author(s):Brown SK;
Address:"CSIRO Building, Construction and Engineering, PO Box 56, Highett, Victoria 3190, Australia. Steve.Brown@dbce.csiro.au"
Journal Title:Indoor Air
Year:2002
Volume:12
Issue:1
Page Number:55 - 63
DOI: 10.1034/j.1600-0668.2002.120107.x
ISSN/ISBN:0905-6947 (Print) 0905-6947 (Linking)
Abstract:"Volatile organic compounds (VOCs) within new and established buildings have been determined and factors significant to their presence have been identified. In established dwellings, total volatile organic compound (TVOC) concentrations were low, but were approximately four times higher than in outdoor air, showing a dominant effect of indoor sources. The presence of attached garages, site contamination and 'faulty' wool carpet were associated with higher indoor pollution. In three dwellings, unidentified sources of benzene were indicated. Much higher VOC concentrations were observed in new or renovated buildings, persisting above 'baseline' levels for several weeks, concentration decay rate correlating with VOC molecular volume, indicating emissions were limited by material diffusion processes. VOC and formaldehyde emission decays in a new dwelling occurred by a double-exponential source model. This shows that persistent low levels of volatile organic pollutants in established dwellings can occur due to long-term emissions from building materials"
Keywords:"Air Pollution, Indoor/*analysis Australia Benzene/analysis Cities Fixatives/analysis Formaldehyde/analysis *Manufactured Materials Organic Chemicals/*analysis Volatilization;"
Notes:"MedlineBrown, S K eng England 2002/04/16 Indoor Air. 2002 Mar; 12(1):55-63. doi: 10.1034/j.1600-0668.2002.120107.x"

 