Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Same length, different shapes: ants collectively choose a straight foraging path over a bent one"    Next AbstractPhysico-chemical and microbiological characterization of spontaneous fermentation of Cellina di Nardo and Leccino table olives »

Rapid Commun Mass Spectrom


Title:Optimization of a large-volume injection method for compound-specific isotope analysis of polycyclic aromatic compounds at trace concentrations
Author(s):Blessing M; Jochmann MA; Haderlein SB; Schmidt TC;
Address:"BRGM, LAB/ISO, 3 avenue Claude Guillemin, BP 36009, F-45060, Orleans cedex 2, France. Instrumental Analytical Chemistry, University Duisburg-Essen, Universitatsstr. 5, D-45141, Essen, Germany. Center for Applied Geoscience (ZAG), Eberhard Karls University Tubingen, Holderlinstr. 12, D-72076, Tubingen, Germany"
Journal Title:Rapid Commun Mass Spectrom
Year:2015
Volume:29
Issue:24
Page Number:2349 - 2360
DOI: 10.1002/rcm.7389
ISSN/ISBN:1097-0231 (Electronic) 0951-4198 (Linking)
Abstract:"RATIONALE: Compound-specific isotope analysis (CSIA) of persistent organic contaminants can be used for source apportioning in the environment if appropriate sensitivity can be achieved. This paper describes the optimization and validation of a sensitive analytical approach for the determination of the carbon isotope composition of semi-volatile organic compounds, such as polycyclic aromatic hydrocarbons (PAHs). METHODS: Analyses are based on the introduction of up to 150 muL of organic extracts by means of programmed temperature vaporization-large-volume injection combined with gas chromatography coupled to isotope ratio mass spectrometry (PTV-LVI-GC/IRMS). To allow for the analysis of more volatile, low-molecular-weight PAHs, the PTV injector was equipped with a sub-ambient/cryogenic cooling. Accuracy, precision, linearity and determination limits for application in isotope analysis were evaluated for a set of individual PAHs ranging from two- to five-ring molecular structures. The method was exemplified by determining the delta(13) C values of individual PAHs in soil samples in a source apportionment study at a contaminated site. RESULTS: The choice of PTV injection parameters is crucial to prevent isotope fractionation during injection and largely depends on the analytes to be determined. The observed isotope fractionation effect on semi-volatiles depends on the applied solvent and injection temperature and demonstrates the importance of performing appropriate tests with given PTV parameters for each of the compounds of interest. The proposed PTV-LVI-GC/IRMS method allows the carbon isotope ratio (delta(13) C value) of individual PAHs to be determined accurately and precisely at concentrations of 0.04-0.1 ng muL(-1) even for volatile PAHs such as naphthalene or acenaphthene. CONCLUSIONS: LVI with PTV injector cooling allows for the isotopic analysis of volatile and semi-volatile PAHs at trace concentrations, thus considerably expanding the applicability of CSIA in environmental studies"
Keywords:
Notes:"PubMed-not-MEDLINEBlessing, Michaela Jochmann, Maik A Haderlein, Stefan B Schmidt, Torsten C eng England 2015/11/14 Rapid Commun Mass Spectrom. 2015 Dec 30; 29(24):2349-60. doi: 10.1002/rcm.7389"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024