Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Sensory, olfactometric and chemical characterization of the aroma potential of Garnacha and Tempranillo winemaking grapes"    Next AbstractUnlocking the Carbyne-Enriched Nanocoating Sensitivity to Volatile Organic Vapors with Plasma-Driven Deposition onto Bulk Micromachined Silicon Membranes »

Sensors (Basel)


Title:Study of Room Temperature Ionic Liquids as Gas Sensing Materials in Quartz Crystal Microbalances
Author(s):Aleixandre M; Nakamoto T;
Address:"Institute of Innovative Research, Tokyo Institute of Technology, Yokohama 226-8503, Japan"
Journal Title:Sensors (Basel)
Year:2020
Volume:20200720
Issue:14
Page Number: -
DOI: 10.3390/s20144026
ISSN/ISBN:1424-8220 (Electronic) 1424-8220 (Linking)
Abstract:"Twenty-eight quartz crystal microbalance (QCM) sensors coated with different sensing films were tested and analyzed in this work; twenty-three sensors were coated in different room temperature ionic liquids (RTILs) and five additional QCM sensors were coated with conventional films commonly used as stationary phases in gas chromatography. Four volatile organic compounds (VOCs), in gaseous phase-hexanol, butyl acetate, 2-hexanone, and hexanoic acid-were measured. Two transducer mechanisms were used; resonant frequency shift and resistance shift of a QCM Mason equivalent circuit. The sensors were characterized by their sensitivity to the VOCs and their discrimination power of the four VOCs. The highest separation among VOCs was obtained when frequency and resistance information of both RTIL and conventional films was used, a sensor array composed by two RTILs (1-butyl-1-methylpyrrolidinium bis(trifluoromethanesulfonyl)imide and 1-hexyl-3-methylimidazolium hexafluorophosphate) and two conventional films (tricresyl phosphate and apiezon-L) was found to improve the Wilks lambda separation for the tested gases two orders of magnitude compared to the Wilks lambda using only a conventional films array"
Keywords:electronic nose gas chromatography stationary phase gas sensor polar and non-polar quartz crystal microbalance room temperature ionic liquid;
Notes:"PubMed-not-MEDLINEAleixandre, Manuel Nakamoto, Takamichi eng JP18H03773/Japan Society for the Promotion of Science/ Switzerland 2020/07/24 Sensors (Basel). 2020 Jul 20; 20(14):4026. doi: 10.3390/s20144026"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024