Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractRemoval of C9-aldehydes and -alcohols from melon juice via cysteine addition    Next AbstractVolatile Profile of Strawberry Fruits and Influence of Different Drying Methods on Their Aroma and Flavor: A Review »

J Chromatogr A


Title:Sensitivity and resolution optimization in gas chromatography coupled to mass spectrometry analyses of volatile organic compounds present in vacuum environment
Author(s):Abou Mrad N; Werner S; Mouzay J; Danger G;
Address:"Aix-Marseille Universite, CNRS, PIIM, UMR 7345, 13013 Marseille, France; Universite Paris-Sud 11, LETIAM, IUT d'Orsay, Plateau de Moulon, 91400 Orsay, France. Aix-Marseille Universite, CNRS, PIIM, UMR 7345, 13013 Marseille, France. Aix-Marseille Universite, CNRS, PIIM, UMR 7345, 13013 Marseille, France. Electronic address: gregoire.danger@univ-amu.fr"
Journal Title:J Chromatogr A
Year:2020
Volume:20190827
Issue:
Page Number:460489 -
DOI: 10.1016/j.chroma.2019.460489
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"The gaseous phase analyses of volatile organic compounds (VOCs) are an important challenge especially when these organics are formed in high vacuum environments (10(-8) mbar) reproducing the environment of astrophysical ices formation and processing. Several analytical techniques have been developed to identify the molecular diversity formed from the processing of these ices. Among them, the coupling of a GC-MS to the vacuum chamber where ices are processed highlighted the interesting chemical diversity of such processed ices. These analyses were possible due to the development of a specific system, the VAHIIA interface that enables the preconcentration of VOCs at low pressure (10(-8) mbar) and their transfer at higher pressure to the injection unit of a GC for their subsequent analyses. This system showed sufficient repeatability (13%) and low detection limits (nmol) for simple ices [1], but presents limits when ice mixtures are complex (such as multi-component ices including water, methanol and ammonia). In this contribution, we present the optimization of our previous VAHIIA system by implementing a cryofocusing system in the GC oven and by improving the recovery yield of VOCs from the vacuum chamber to the VAHIIA interface. The cryofocusing provides an improvement of efficiencies leading to higher resolution and signal to noise ratio, while the addition of argon in the vacuum chamber during the VOC recovery allows increasing the amount of molecules recovered by a factor of approximately 200. The coupling of both approaches provides an increase of sensitivity of a factor approximately 400. At the end, experiments on astrophysical ices are shown demonstrating the interest of such optimizations for VOC analyses"
Keywords:Gas Chromatography-Mass Spectrometry/instrumentation/*methods Sensitivity and Specificity Vacuum Volatile Organic Compounds/*chemistry Cryofocusing Gc-ms Ice analogs Vacuum environment Volatile Organic Compounds;
Notes:"MedlineAbou Mrad, Ninette Werner, Steven Mouzay, Julie Danger, Gregoire eng Evaluation Study Netherlands 2019/09/12 J Chromatogr A. 2020 Jan 4; 1609:460489. doi: 10.1016/j.chroma.2019.460489. Epub 2019 Aug 27"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024