Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEnhanced stable long-term operation of biotrickling filters treating VOCs by low-dose ozonation and its affecting mechanism on biofilm    Next AbstractCharacterization of the Aroma-Active Compounds in Commercial Fragrant Rapeseed Oils via Monolithic Material Sorptive Extraction »

Appl Bionics Biomech


Title:Development of a Novel Micro Photoionization Detector for Rapid Volatile Organic Compounds Measurement
Author(s):Zhou Q; Zhang S; Zhang X; Ma X; Zhou W;
Address:"School of Mechanical Engineering, Hebei University of Technology, Tianjin 300130, China. School of Mechanical Engineering, Tianjin University of Technology and Education, Tianjin 300130, China. School of Electrical and Electronic Engineering, Tianjin University of Technology, Tianjin 300130, China"
Journal Title:Appl Bionics Biomech
Year:2018
Volume:20180905
Issue:
Page Number:5651315 -
DOI: 10.1155/2018/5651315
ISSN/ISBN:1176-2322 (Print) 1754-2103 (Electronic) 1176-2322 (Linking)
Abstract:"The simulation of the gas flow field and electrostatic field in the photoionization detector by COMSOL was conducted based on principle investigation in the present study. Under the guidance of simulation results, structural optimization was carried out to significantly reduce the dead volume of the ionization chamber, and finally, the relationship between offset voltage and collection efficiency was obtained which led to a remarkable increase in the collection efficiency of charged ions in the photoionization detector. Then an ionization chamber with low interference and fast response was developed. Then experiment was performed with toluene as a VOCs gas under the condition of optimal gas flow rate of 50 ml, UV lamp ionization energy of 10.86 eV. The results showed that the ion collection efficiency reached 91% at a bias voltage of 150 V. Moreover, a preferred linearity of 99.99% was obtained, and a ppb level of LOD can be achieved. The determination results well-fitted the relationship between offset voltage and the response value obtained in the simulation"
Keywords:
Notes:"PubMed-not-MEDLINEZhou, Qi Zhang, Sixiang Zhang, Xu Ma, Xu Zhou, Wei eng Egypt 2018/09/27 Appl Bionics Biomech. 2018 Sep 5; 2018:5651315. doi: 10.1155/2018/5651315. eCollection 2018"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024