« Previous AbstractBiochar increases Panax notoginseng's survival under continuous cropping by improving soil properties and microbial diversity    Next AbstractEffects of Different Probiotics on the Volatile Components of Fermented Coffee Were Analyzed Based on Headspace-Gas Chromatography-Ion Mobility Spectrometry »

Build Simul


Title:Experimental and numerical investigation of TVOC concentrations and ventilation dilution in enclosed train cabin
Author(s):Zhao L; Zhou H; Jin Y; Li Z;
Address:"Key Laboratory of Fluid Transmission Technology of Zhejiang Province, Zhejiang Sci-Tech University, Hangzhou, 310018 China. GRID: grid.413273.0. ISNI: 0000 0001 0574 8737 Hangzhou Yunze Environmental Technology Co., Ltd, Hangzhou, China"
Journal Title:Build Simul
Year:2022
Volume:20210910
Issue:5
Page Number:831 - 844
DOI: 10.1007/s12273-021-0827-2
ISSN/ISBN:1996-3599 (Print) 1996-8744 (Electronic) 1996-3599 (Linking)
Abstract:"Air pollution in trains is an important factor threatening human health, which has attracted more and more attention in the worldwide public health researches. In this study, one cabin of a fully enclosed train was taken as an example to conduct experimental and numerical research on pollution level and distribution characteristic of total volatile organic compound (TVOC). The results show that when the average emission rate under daily environmental conditions was taken as the reference, TVOC concentration in the cabin exceeded the limit level of Chinese Indoor Air Quality Standard by more than 4 times. The obvious pollutants accumulative phenomenon could be found at bottoms and corners under the action of airflow. Setting air inlets at the roof of the train, mean age of air ranged from 30 s to 50 s in the breathing area. The concentration of pollutants was the lowest at 2.5-5 m from the center point of the cabin structure, and the ventilation efficiency was the highest. The introduction of clean fresh air could effectively eliminate pollutants. When the complete displacement ventilation rates were 51.4 h(-1) and 28.6 h(-1), the removal efficiency of pollutants was about 0.85 and 0.48 mg/m(3) per minute, respectively. This study was helpful to the improvement and optimization design of air quality and ventilation mode in trains"
Keywords:Cfd VOCs indoor air quality railway cabins ventilation dilution;
Notes:"PubMed-not-MEDLINEZhao, Le Zhou, Huang Jin, Yuzhen Li, Zeqing eng China 2021/09/16 Build Simul. 2022; 15(5):831-844. doi: 10.1007/s12273-021-0827-2. Epub 2021 Sep 10"

 