Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDifferential regulation of Tec1 by Fus3 and Kss1 confers signaling specificity in yeast development    Next AbstractInsect eggs suppress plant defence against chewing herbivores »

J Am Soc Mass Spectrom


Title:Detection of Volatile Organic Compounds with Secondary Electrospray Ionization and Proton Transfer Reaction High-Resolution Mass Spectrometry: A Feature Comparison
Author(s):Bruderer T; Gaugg MT; Cappellin L; Lopez-Hilfiker F; Hutterli M; Perkins N; Zenobi R; Moeller A;
Address:"Department of Chemistry and Applied Biosciences, Swiss Federal Institute of Technology, 8093 Zurich, Switzerland. Division of Respiratory Medicine, University Children's Hospital Zurich and Children's Research Center Zurich, 8032 Zurich, Switzerland. TOFWERK AG, 3645 Thun, Switzerland. Dipartimento di Scienze Chimiche, Universita degli Studi di Padova, 35131 Padua, Italy. Research and Innovation Centre, Fondazione Edmund Mach, 38010 San Michele all'Adige, Italy. Clinical Chemistry and Biochemistry, University Children's Hospital Zurich, 8032 Zurich, Switzerland"
Journal Title:J Am Soc Mass Spectrom
Year:2020
Volume:20200713
Issue:
Page Number: -
DOI: 10.1021/jasms.0c00059
ISSN/ISBN:1879-1123 (Electronic) 1044-0305 (Linking)
Abstract:"The analysis of volatiles is of high relevance for a wide range of applications from environmental air sampling and security screening to potential medical applications. High-resolution mass spectrometry methods offer a particularly wide compound coverage, sensitivity, and selectivity. Online approaches allow direct analysis in real time without the need for sample preparation. For the first time, we systematically compared the analysis of volatile organic compounds with secondary electrospray ionization (SESI) and proton transfer reaction (PTR) high-resolution mass spectrometry. The selected instruments had comparable mass resolving powers with m/Deltam >/= 15000, which is particularly suitable for nontargeted analysis, for example, of exhaled breath. Exhalations from 14 healthy adults were analyzed simultaneously on both instruments. In addition, 97 reference standards from nine chemical classes were analyzed with a liquid evaporation system. Surprisingly, in breath, we found more complementary than overlapping features. A clear mass dependence was observed for each method with the highest number of detected m/z features for SESI in the high mass region (m/z = 150-250) and for PTR in the low mass region (m/z = 50-150). SESI yielded a significantly higher numbers of peaks (828) compared to PTR (491) among a total of 1304 unique breath m/z features. The number of signals observed by both methods was lower than expected (133 features) with 797 unique SESI features and 374 unique PTR features. Hypotheses to explain the observed mass-dependent differences are proposed"
Keywords:
Notes:"PublisherBruderer, Tobias Gaugg, Martin T Cappellin, Luca Lopez-Hilfiker, Felipe Hutterli, Manuel Perkins, Nathan Zenobi, Renato Moeller, Alexander eng 2020/06/26 J Am Soc Mass Spectrom. 2020 Jul 13. doi: 10.1021/jasms.0c00059"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024