Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractNew analogues of (E)-beta-farnesene with insecticidal activity and binding affinity to aphid odorant-binding proteins    Next AbstractElevated CO2 increases the abundance of the peach aphid on Arabidopsis by reducing jasmonic acid defenses »

J Environ Sci (China)


Title:Determination of gaseous semi- and low-volatile organic halogen compounds by barrier-discharge atomic emission spectrometry
Author(s):Sun Y; Watanabe N; Wang W; Zhu T;
Address:"School of Chemistry and Environment, Key Laboratory of Bio-Inspired Smart Interfacial Science and Technology of Ministry of Education, Beihang University, Beijing 100191, China. sunif@buaa.edu.cn"
Journal Title:J Environ Sci (China)
Year:2013
Volume:25
Issue:1
Page Number:213 - 219
DOI: 10.1016/s1001-0742(12)60032-1
ISSN/ISBN:1001-0742 (Print) 1001-0742 (Linking)
Abstract:"A group parameter approach using 'total organic halogen' is effective for monitoring gaseous organic halogen compounds, including fluorine, chlorine, and bromine compounds, generated from combustion. We described the use of barrier-discharge radiofrequency-helium-plasma/atomic emission spectrometry, for the detection of semi- and low-volatile organic halogen compounds (SLVOXs), which can be collected by Carbotrap adsorbents and analyzed using thermal desorption. The optimal carrier gas flow rates at the injection and desorption lines were established to be 100 mL/min. The detection range for SLVOXs in the gaseous samples was from 10 ng to tens of micrograms. Measuring F was more difficult than measuring C1 or Br, because the wavelength of F is close to that of air. The barrier-discharge radiofrequency-helium-plasma/atomic emission spectrometry measured from 85% to 103% of the SLVOXs in the gas sample. It has been found that Carbotrap B is appropriate for high-boiling-point compounds, and Carbotrap C is suitable for the determination of organic halogen compounds with lower boiling points, in the range 200-2300C. Under optimal analysis conditions, a chlorine-containing plastic was destroyed using different oxygen concentrations. Lower oxygen concentrations resulted in the production of lower amounts of organic halogen compounds"
Keywords:Halogens/*analysis Oxygen/chemistry Volatile Organic Compounds/*analysis;
Notes:"MedlineSun, Yifei Watanabe, Nobuhisa Wang, Wei Zhu, Tianle eng Research Support, Non-U.S. Gov't Netherlands 2013/04/17 J Environ Sci (China). 2013 Jan 1; 25(1):213-9. doi: 10.1016/s1001-0742(12)60032-1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024