Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractInstantaneous analysis of aldehydes in biological fluids using a spray interface coupled to a mass spectrometer    Next AbstractIntake of toxic and carcinogenic volatile organic compounds from secondhand smoke in motor vehicles »

Environ Res


Title:"Indoor air quality in Montreal area day-care centres, Canada"
Author(s):St-Jean M; St-Amand A; Gilbert NL; Soto JC; Guay M; Davis K; Gyorkos TW;
Address:"Health Canada, Air Quality Programs Division, Water, Air and Climate Change Bureau, Ottawa, Ontario, Canada. melissa.st-jean@hc-sc.gc.ca"
Journal Title:Environ Res
Year:2012
Volume:20120801
Issue:
Page Number:1 - 7
DOI: 10.1016/j.envres.2012.07.001
ISSN/ISBN:1096-0953 (Electronic) 0013-9351 (Linking)
Abstract:"Indoor air quality (IAQ) has been understudied in day-care centres (DCCs), even though it can affect the respiratory health of children. This study was undertaken to assess IAQ in a randomly selected sample of 21 DCCs having space for at least 40 children in Montreal, Canada, and to determine associations between building characteristics and IAQ. Questionnaires on building characteristics and operation of the DCC were administered to managers. Temperature, relative humidity, and concentrations of carbon dioxide (CO(2)), formaldehyde and volatile organic compounds were measured in January and February 2008 in rooms attended by children aged between 18 and 60 months. Most DCCs (81%) had a mechanical ventilation system. Over 85% of the DCCs had a mean CO(2) concentration higher than 1000 ppm, the value generally targeted for comfort in buildings. Mean CO(2) concentrations were significantly lower in DCCs having a floor space meeting the provincial standards. The mean (standard deviation-SD) formaldehyde concentration was 22.9 (8.2) mug/m(3), with all participating DCCs being within Health Canada's Residential IAQ Guideline of 50 mug/m(3). The presence of a mechanical ventilation system and a large surface of play area per child were significantly associated with lower CO(2) levels, explaining 44% of the variance in indoor CO(2) concentrations. The presence of a mechanical ventilation system was also associated with significantly lower formaldehyde and acetaldehyde levels. Moreover, 68% of the variance in indoor acetaldehyde concentrations was explained by CO(2) levels, indicating that CO(2) was a better proxy of ventilation than the presence of a ventilation system, as this latter variable did not imply that the ventilation system was running or functioning adequately. These results demonstrate the need for on-going efforts to ensure sufficient floor space and adequate ventilation in DCCs to maintain good IAQ"
Keywords:"*Air Pollution, Indoor Child *Child Day Care Centers Humans Quebec Surveys and Questionnaires Volatile Organic Compounds/analysis;"
Notes:"MedlineSt-Jean, Melissa St-Amand, Annie Gilbert, Nicolas L Soto, Julio C Guay, Mireille Davis, Karelyn Gyorkos, Theresa W eng Research Support, Non-U.S. Gov't Netherlands 2012/08/04 Environ Res. 2012 Oct; 118:1-7. doi: 10.1016/j.envres.2012.07.001. Epub 2012 Aug 1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024