Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract[Indoor air pollution by volatile organic compounds in large buildings: pollution levels and remaining issues after revision of the Act on Maintenance of Sanitation in Buildings in 2002]    Next AbstractAlternative suppression of transcription from two desaturase genes is the key for species-specific sex pheromone biosynthesis in two Ostrinia moths »

Sci Total Environ


Title:"Characterization and source profiling of volatile organic compounds in indoor air of private residences in Selangor State, Malaysia"
Author(s):Sakai N; Yamamoto S; Matsui Y; Khan MF; Latif MT; Ali Mohd M; Yoneda M;
Address:"Division of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto 6158540, Japan; Shimadzu-UMMC Centre of Xenobiotic Studies, Department of Pharmacology, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia. Electronic address: sakai@risk.env.kyoto-u.ac.jp. Division of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto 6158540, Japan. Research Centre for Tropical Climate Change System (IKLIM), Institute of Climate Change, Universiti Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia. School of Environment and Natural Resource Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia; Institute for Environment and Development (LESTARI), Universiti Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia. Shimadzu-UMMC Centre of Xenobiotic Studies, Department of Pharmacology, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia"
Journal Title:Sci Total Environ
Year:2017
Volume:20170222
Issue:
Page Number:1279 - 1286
DOI: 10.1016/j.scitotenv.2017.02.139
ISSN/ISBN:1879-1026 (Electronic) 0048-9697 (Linking)
Abstract:"Volatile Organic Compounds (VOCs) in indoor air were investigated at 39 private residences in Selangor State, Malaysia to characterize the indoor air quality and to identify pollution sources. Twenty-two VOCs including isomers (14 aldehydes, 5 aromatic hydrocarbons, acetone, trichloroethylene and tetrachloroethylene) were collected by 2 passive samplers for 24h and quantitated using high performance liquid chromatography and gas chromatography mass spectrometry. Source profiling based on benzene/toluene ratio as well as statistical analysis (cluster analysis, bivariate correlation analysis and principal component analysis) was performed to identify pollution sources of the detected VOCs. The VOCs concentrations were compared with regulatory limits of air quality guidelines in WHO/EU, the US, Canada and Japan to clarify the potential health risks to the residents. The 39 residences were classified into 2 groups and 2 ungrouped residences based on the dendrogram in the cluster analysis. Group 1 (n=30) had mainly toluene (6.87+/-2.19mug/m(3)), formaldehyde (16.0+/-10.1mug/m(3)), acetaldehyde (5.35+/-4.57mug/m(3)) and acetone (11.1+/-5.95mug/m(3)) at background levels. Group 2 (n=7) had significantly high values of formaldehyde (99.3+/-10.7mug/m(3)) and acetone (35.8+/-12.6mug/m(3)), and a tendency to have higher values of acetaldehyde (23.7+/-13.5mug/m(3)), butyraldehyde (3.35+/-0.41mug/m(3)) and isovaleraldehyde (2.30+/-0.39mug/m(3)). The 2 ungrouped residences showed particularly high concentrations of BTX (benzene, toluene and xylene: 235mug/m(3) in total) or acetone (133mug/m(3)). The geometric mean value of formaldehyde (19.2mug/m(3)) exceeded an 8-hour regulatory limit in Canada (9mug/m(3)), while those in other compounds did not exceed any regulatory limits, although a few residences exceeded at least one regulatory limit of benzene or acetaldehyde. Thus, the VOCs in the private residences were effectively characterized from the limited number of monitoring, and the potential health risks of the VOCs exposure, particularly formaldehyde, should be considered in the study area"
Keywords:"Air Pollution, Indoor/*analysis *Environmental Monitoring Housing Malaysia Volatile Organic Compounds/*analysis Characterization Gc-ms Hplc Indoor air Source profiling Volatile organic compounds;"
Notes:"MedlineSakai, Nobumitsu Yamamoto, Shuta Matsui, Yasuto Khan, Md Firoz Latif, Mohd Talib Ali Mohd, Mustafa Yoneda, Minoru eng Netherlands 2017/02/27 Sci Total Environ. 2017 May 15; 586:1279-1286. doi: 10.1016/j.scitotenv.2017.02.139. Epub 2017 Feb 22"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024